Before installing your White Knight product, please carefully review the product manual. There are many helpful hints and ways to optimize the set up and use of your White Knight product as well as instructions and requirements for installation. In addition, there are many accessories in this manual that will enhance the functionality of your White Knight product.
White Knight pump will nullify this warranty. The PPMC300 metering pump is warranted for up to 100 PSI air supply pressures, and 160 PSI discharge pressures. Wearable parts are not covered if used to pump abrasive slurries.
NEMA 5 Applications The PPMC300 is capable of NEMA 5 classification. However, this requires that the end user route the vent air to a safe location. The port is located on the front of the pump housing and is assembled and shipped with an orifice plug to allow for immediate use upon arrival.
4.2 System and Pump Environment Recommendations/Requirements Clean Supply Air (CDA) White Knight high purity pumps require the use of Class 2 air for particles and moisture per ISO 8573-1. (Use 10- micron filter, maintain -40° C dew point) Environmental Temperature This pump is rated to withstand environmental temperatures up to 80°C.
5.1 Wire Connectors / Wire Leads The PPMC300 has Turck EuroFast male receptacle coming out of the front of the device. This connector both powers the on board controls and provides external I/O for the device. A mating cable is available and wire colors shown in the diagram relate to the optional cable.
The digital signals work with NPN or Sink type digital connections. An example digital control signal is shown below: Note: The CPT-1 is a pump controller offered by White Knight and is capable of operating the PPMC300 in digital control mode.
1. Return the pump to White Knight for a full evaluation, failure analysis, and quote issued by White Knight or our local distributor. Upon the acceptance of the quote in the form of a purchase order the pump will be rebuilt as outlined in the quote.
White Knight products are designed for use with caustic and otherwise dangerous liquids. Therefore, every product must be handled as if it contains dangerous chemicals. White Knight specifies that if a pump runs under its own power, the pump should circulate DI water for twenty minutes before disassembly or double-bagging for shipment.
Page 18
Manual Version 1.0.7 Manual Part Number: 18200-LM-0066...