For example, product assembly and testing is done in a temperature and humidity-controlled cleanroom. Please peruse this manual before installing your White Knight product. It details installation requirements and setup instructions, and provides additional information and accessories to enhance the product’s functionality.
PSD pumps that are not put into operation upon delivery must be stored in an environment where they are protected from moisture, extreme temperatures, UV radiation, vibration, and should be kept clean. White Knight recommends an environment of ambient temperature (between 60° F (15°C) and 80°F (25°C)) with a humidity level below 65%.
Required Air Flow and Operating Pressure Required Air Flow for the PSD24 is ⅜” minimum orifice unrestricted at 2 meters lengths or lower, larger lengths may require a larger diameter for full flow. An adaptor is included for ½” NPT or ½” BSPT with all pumps, NPT or BSPT is decided on based on the liquid fittings requested.
3.2 PSD Installation Advantages Head Pressure / Dead-Head White Knight PSD pumps may be controlled by opening and closing the outlet of the pump and may be installed in any head pressure situation up to dead-head. Dead-head occurs when air supply pressure and the liquid line (head) pressure are equal.
435.783.6040 888.796.2476 4.3 Configurable Rebuild Ordering Instructions Pages 12 and 13 list the standard rebuild kits White Knight offers. Use this section for alternate rebuild kits not found in the previous section. Air Motors do not need to be removed from the Air Motor pump for service.
Failures due to misuse, abuse or any unauthorized disassembly of a White Knight pump will nullify this warranty. The PSD24 pump is warranted for up to 100 PSI air supply pressures. It is not covered under dry run condition. Wearable parts are not covered.