IMPORTANT SAFETY DETAILS
1.
Hazardous voltage may be present at the output of the dimmer despite setting the dimmer to zero brightness
level. Look out and tag the input circuit before accessing the wiring connections. Failure to follow this warning can
result in death or serious injury.
2.
Ensure the AC/Mains power is NOT connected and cannot be unexpectedly reconnected during installation.
3.
This dimmer shall be protected by a 6A or up to a 10A maximum miniature circuit breaker, which is special use
with this dimmer.
4.
This product must be installed by a qualified electrician in accordance with instructions provided and in
compliance with recognised electrical and safety regulations relevant to the country it is being installed.
5.
This product may NOT be installed by minors or people with a mental disability.

INSTALLATION DETAILS

ONE WAY OPERATION
Load
Load
MULTI WAY OPERATION
1.
Disconnect power. Lock out and tag the relevant circuit at the mains switchboard.
2.
Remove existing switch from wall.
3.
Connect the dimmer in accordance with the wiring diagrams.
*the copper conductors for the terminals is 1,0 to 1,5mm rigid wire.
4.
Refit switch plate to wall and fit the dimmer knob to the shaft.
5.
Reconnect power. Push ON and dim with turning knob.
NOTE:
The Dimmer must always be connected to the LINE side of the load. Multi-way retractive switch or push switch can
control up to 20 units for UP/DOWN dim and ON/OFF function. Two or more dimmers MUST NOT be connected in
parallel or series to control the same load from two different locations.