en Home Connect
a The ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
a Automatic mode runs for a maximum of four hours.
6.11 Sensor control
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
timum fan setting is automatically switched on. If the
sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡ Factory setting: 5
¡ Lowest setting: 0
¡ Highest setting: 9
6.12 Setting the sensor control
Requirement: The appliance is switched off.
Press and hold
​ ⁠ .
1.
a The setting is displayed after approx. one second.
Press
​ ⁠   or  ​ ⁠ to change the setting.
2.
Release 
​ ⁠ to save the setting.
3.
6.13 Switching on the lighting
The lighting can be switched on and off independently
of the ventilation system.
Note: Colour temperature settings are available in the
Home Connect app provided the appliance has this
function.
Press
​ ⁠ .
6.14 Setting the brightness
Press and hold
​ ⁠ until the required brightness is
reached.
7  Home Connect
This appliance is network-capable. Connecting your ap-
pliance to a mobile device lets you control its functions
via the Home Connect app, adjust its basic settings
and monitor its operating status.
The Home Connect services are not available in every
country. The availability of the Home Connect function
depends on the availability of Home Connect services
in your country. You can find information about this at:
www.home-connect.com.
The Home Connect app guides you through the entire
login process. Follow the instructions in the Home Con-
nect app to configure the settings.
8
6.15 Setting the PowerBoost position
On some appliances, the filter cover can be adjusted to
an intermediate position. The intermediate position can
be used to eliminate particularly strong cooking smells
and large amounts of steam.
Take hold of the filter cover in the centre and open it
carefully.
6.16 Resetting the saturation indicator
After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.
Requirements
¡ After the appliance has been switched off,
pears in the display for the grease filter.
¡ After the appliance has been switched off,
pears in the display for the odour filter.
Press  ​ ⁠ .
a The saturation indicator is reset.
6.17 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement: The appliance is switched off.
To set circulating-air mode (non-regenerable filter),
1.
press and hold
​ ⁠ and
play.
To set circulating-air mode (regenerable filter), press
2.
and hold
​ ⁠ and
​ ⁠ until
To set the air extraction mode, press and hold
3.
and
​ ⁠ until
​ ⁠ appears on the display.
6.18 Switching on the audible signal
Requirement: The appliance is switched off.
Press and hold
​ ⁠ and ​ ⁠ at the same time for ap-
prox. three seconds until a signal sounds.
a ​ ⁠ appears on the display.
6.19 Switching off the audible signal
Requirement: The appliance is switched off.
Press and hold
​ ⁠ and ​ ⁠ at the same time for ap-
prox. three seconds until a signal sounds.
​ ⁠ appears on the display.
a
Tips
¡ Please consult the documents supplied by
Home Connect.
¡ Please also follow the instructions in the Home Con-
nect app.
Notes
¡ Please note the safety precautions in this instruction
manual and make sure that they are also observed
when operating the appliance via the Home Con-
nect app.
→ "Safety", Page 2
​ ⁠ ap-
​ ⁠ ap-
​ ⁠ until
​ ⁠ appears on the dis-
​ ⁠
​ ⁠ appears on the display.
​ ⁠