Maintenance Instructions - USECO AFCHCP Series Operation Manual

Table of Contents

Advertisement

MAINTENANCE INSTRUCTIONS

CAUTION
:
Personal Injury Hazard
Disconnect appliance from
electrical power before
cleaning condenser coil.
CAUTION
:
Personal Injury Hazard
Condenser coil fins are sharp.
Use care to avoid cuts while
cleaning the condenser.
CAUTION:
Hot Surface
Exposed surfaces can be hot to
the touch and may cause burns
CONDENSER COIL CLEANING INSTRUCTIONS
The condenser coil must be kept clean to allow adequate
air flow for proper heat dissipation. Recommend this
procedure be performed monthly.
1. Turn POWER SWITCH OFF. Disconnect unit
from electrical power.
2. Remove louvers or access panel to allow coil to be
reached.
3. Using a stiff bristle brush, brush lint and debris from
the condenser fins. Brush vertically, top to bottom.
Collect and discard all lint and debris gathered from
this operation.
IMPORTANT: The fins of the condenser are
delicate and easily damaged. Use care to brush in a
vertical motion to avoid damaging the coil fins.
4. Wipe the fan blades to remove accumulated lint.
5. Reconnect to electrical power. Refer to COLD
Operation (page 7) and test for proper operation.