Press CLEAR & +1 key simultaneously to cleat the batch number from the display. Selection of batch number must
be done before you start counting.

Memory Recall

This machine allows user to view total numbers of coins counted since the machine powered up. To view the total
counting result on the count display follow the steps below.
The indicator light on the ADD/STORE is off ensuring the deactivation of the function
Press RD key, last counting results will display on the count display, such as [R.......XXXXXX]
Press CLEAR to clear all counting results from the memory.
Error Codes
When powering up the coin counter or during counting a series of error messages may appear on the display.

Error Code

Eb0
Coin jamming error. Coins are
jammed near the counting sensor
Ec0
Stop State. A coin is passing
through the sensor without
counting / registering
E04
Side cover is not closed tightly or
open.
Maintenance the CCE 410
This chapter described how to take care of the coin counter, including cleaning and maintenance.
WARNING ! The machine must be off and unplugged from the main socket.
Always switch the power of during cleaning.
Clean the machine with a dry cloth.
Do not use wet or damp cloth or cleaning products.
Do not spill any liquid or spray chemicals over the equipment.
If any liquid is spilled on it, disconnect the power cable from the supply and contact your dealer.
CashConcepts
CCE 410
Meaning
1. Open side cover and remove jammed coins.
2. Close side cover and press CLEAR key to clear error
message
3. Press START / STOP to resume counting
1. Press CLEAR
2. Press START / STOP
Close side cover tightly.