* A Taco 008-BC6 or Grundfos 15-42 BUC7 (or equivalent) circulation pump
is recommended for use with the NFC-H boiler and DHW recirculation
systems.
* When using the external recirculation mode, observe the following
maximum recirculation pipe lengths including fittings (
recommended). Lengths in excess of these limits will require a larger
recirculation pump.
Pipe Diameter
Maximum Pipe Length
Install the NaviCirc recirculation valve on the faucet
Note
furthest from the NFC-H boiler.
If installed in close proximity to the boiler, faucets
further down the supply line will take longer to
receive hot water.
Maximum Pipe Lengths
1
/
100 ft (30 m)
82
"
2
3
/
" pipe is
4
3
/
"
4
400 ft (120 m)