Navien NaviCirc Installation And Operation Manual page 79

Table of Contents

Advertisement

T/S_ZONE2
T/S_ZONE1
T/S_ZONE1
C
R
C
R
C
R
C
C
W
W
W
Thermostat 2
Thermostat 1
Thermostat 1
lLWCO
lLWCO
AC24VL
AC24VL
AC24VN
AC24VN
Recirculation
Timer, Aquastat,
or HotButton
Push Button
* If the DHW recirculation
menu is set to the Always On,
Intelligent, or Weekly option,
no aquastat or additional
HotButton is required.
Note
When using combi pre-
heat, using a recirculation
pump is not necessary.
Select combi pre-heat on
the DHW recirculation
menu.
When using external
recirculation, install
a recirculation pump
and select external
recirculation in the DHW
Recirculation
recirculation menu.
Timer, Aquastat,
or HotButton
Push Button
79