The Dragon K85 Mobile Furnace is a diesel fuel- and
electric-powered indirect fired heater. It provides
heated air without adding moisture for a variety of
applications, including water damage restoration,
structural drying, construction, and temporary event
shelters.
Safety Information
Read this Owner's Manual carefully to learn how to
properly operate and service your Dragon K85 Mobile
Furnace. This manual should be considered a
permanent part of the machine and should remain
with the Dragon if you sell it.
Failure to comply with the instructions and precautions
provided in this Owner's Manual can result in death,
serious bodily injury, and/or property loss or damage
from hazards of fire, explosion, burn, asphyxiation,
carbon monoxide poisoning, and/or electrical shock.
Electrical Connections
The Dragon K85 Mobile Furnace is designed to
operate on a 115V/60 Hz electrical connection. Make
sure that the electrical outlet is grounded with three
prongs. When using with an extension cord, use only a
grounded cord intended for outdoor use and rated to
deliver enough power to the Dragon (4.4 amps@115V
or 506W).
Fuel Type
The Dragon K85 Mobile Furnace is designed to
operate on diesel #2 fuel oil only. The Dragon can
operate for a minimum of 8 hours using the internal
tank that holds 9.3 gallons (35 L). Do not run the
Dragon out of fuel, as it may be difficult to restart. For
longer unattended use, it is recommended that you
purchase a larger, DOT-approved external fuel tank to
use with the external fuel siphon.
If external tank is used, cover opening to prevent
contaminants from entering tank. Place tank on
flat, stable surface to prevent tipping or spilling.
07-00407F 02/2008
Failure to use diesel fuel could cause injury and
permanent damage to the unit. It may also void the
Dri-Eaz warranty.
Altitude Adjustment
NOTICE: The Dragon is factory-set for use at
elevations up to 2000 feet above sea level. For use
above 2000 feet or for any subsequent change of
elevation, higher or lower, the unit must be adjusted by
a qualified HVAC technician to avoid excessive soot
build-up and possible flue fire. Always have a qualified
HVAC technician adjust the unit for operating at the
altitude of the intended use. Failure to adjust for
altitude changes could cause injury, permanent
damage to the unit and secondary damage when
ducting into a structure. It may also void the Dri-
Eaz warranty. Black or gray/white smoke coming from
the flue indicates an improper air to fuel ratio and that
the unit must be adjusted. Call an HVAC specialist for
assistance, or an authorized service center for referral
to an HVAC technician. For further questions, call Dri-
Eaz Service at 800-932-3030.
OVERVIEW
Introduction
The Dragon K85 Mobile Furnace is an indirect fired
heater. It supplies heated air to an area without adding
any moisture or fumes through the heating process.
The Dragon is able to do this by using a heat
exchanger so that the process air never comes into
direct contact with the flame in the combustion
chamber.
The Dragon operates from outside the structure. It
draws in the ambient outdoor air and increases its
temperature by 81°F. An electric fan directs this
heated air into the structure through ducting. The
remote thermostat automatically cycles the Dragon on
and off to maintain a preset temperature in the
affected area.
The clean, dry heat from the Dragon helps reduce
drying times while maintaining stable and comfortable
temperatures. The Dragon is ideal for any number of
applications, including:
water damage restoration
new construction drying
unheated jobsites
temporary event shelters
any situation calling for clean, dry heat
Principles of Use
For applications like water damage restoration and
new construction drying, the Dragon can increase
drying efficiency.
1
Copyright 2006 Dri-Eaz Products, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dragon K85 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dri-Eaz Dragon K85

  • Page 1 It may also void the Dri- The Dragon K85 Mobile Furnace is a diesel fuel- and Eaz warranty. Black or gray/white smoke coming from electric-powered indirect fired heater. It provides...
  • Page 2: Parts Identification

    60%RH to avoid secondary damage to the structure and contents. Rear Handle Air Intake Grill Accessories Included Flue The Dragon K85 Mobile Furnace includes the following Ducting parts and accessories: Fuel line guard plate Internal tank fuel lines Dragon K85 Mobile Furnace...
  • Page 3 The Dragon is shipped with an empty fuel tank. Before NOTICE: Keep air intake vents under unit clean and operating, fill the internal tank with diesel #2 fuel oil clear of any obstruction. Avoid setting up unit where 07-00407F 02/2008 Copyright 2006 Dri-Eaz Products, Inc.
  • Page 4 2. Drill two 1/8-inch holes through the bottom of the flue into the heat exchanger pipe. The holes should be approximately 90 degrees apart. Clamp the ducting securely to the duct ring Drill two 1/8-inch holes in the flue 07-00407F 02/2008 Copyright 2006 Dri-Eaz Products, Inc.
  • Page 5 4. Slip a hose clamp (not included) over the free end of one of the 30-foot lengths of 8-inch diameter aluminum ducting. Slide the ducting over the adapter and secure firmly with the hose clamp. 5. Secure the plywood to the structure. 07-00407F 02/2008 Copyright 2006 Dri-Eaz Products, Inc.
  • Page 6: Programming The Thermostat

    3. Place a TurboDryer, Vortex Axial Fan, or other airmover so that it forces air out of the affected area to the outdoors through the selected opening. The airmover should remove at least 800 CFM from the affected area. 07-00407F 02/2008 Copyright 2006 Dri-Eaz Products, Inc.
  • Page 7 Press the up or down arrow keys to select a Choose either Fahrenheit (F) or Celsius (C) mode differential. You can select a differential from 1°F to 30°F. Use the arrows to select a differential 07-00407F 02/2008 Copyright 2006 Dri-Eaz Products, Inc.
  • Page 8: Special Instructions

    212°F (100°C), the Dragon will automatically shut If the heater continues to shut off due to thermal down due to thermal overload and must be reset overload, contact the Dri-Eaz Service Department at before it will start again. The most common cause of 888-867-3235.
  • Page 9 Do not smoke while connecting fuel tanks. Keep Using an external fuel tank away from open flame. The internal fuel tank of the Dragon K85 Mobile 1. Remove the external fuel siphon from the external Furnace has a capacity of 9.3 gallons (35 L).
  • Page 10: Maintenance

    "Setting up the Dragon." However, you do not need to add fuel, attach the flue, or connect the remote thermostat. As a ventilator the Dragon will operate on electricity alone. 2. Turn the FAN switch to “On.” 07-00407F 02/2008 Copyright 2006 Dri-Eaz Products, Inc.
  • Page 11 To do this, remove the six Phillips screws that secure the housing cover and guard plate. 2. Close the fuel line shut-off valve by turning the red knob clockwise. Unscrew the fuel intake filter by hand 07-00407F 02/2008 Copyright 2006 Dri-Eaz Products, Inc.
  • Page 12 The cleaning should be performed by a qualified HVAC technician at a local service center. Contact your local distributor or the Dri-Eaz Service Department at 1-888-867-3235 for the location of a service center near you. To clean the Dragon housing, use a cleaner with a ®...
  • Page 13: Specifications

    SPECIFICATIONS MODEL Dragon K85 Mobile Furnace (F260) Model Number F260 Dimensions – HxWxD 28" x 23" x 40" (71 x 58 x 102 cm) Use Weight 188 lb (85 kg) Voltage 115V Frequency 60Hz Power Required 4.4 amps Fuel Consumption 0.69 gal/hr (2.6 L/hr)