Mobile furnace

Advertisement

Quick Links

The Dragon 3600 Mobile Furnace is an indirect fired furnace providing heated air for water damage
restoration, structural drying, construction, event shelters and other temporary heating applications.
R E A D A N D S A V E T H E S E I N S T R U C T I O N S
WARNING
WARNING! Failure to comply with the instructions
and precautions provided in this Owner's Manual
can result in death, serious bodily injury, and/or
property loss or damage from hazards of fire,
explosion, burn, asphyxiation, carbon monoxide
poisoning, and/or electrical shock.
WARNING! Do not alter or modify this unit in any
way. Use only replacement parts authorized by Dri-
Eaz Products, Inc. Modifications or use of
unapproved parts could create a hazard and will
void your warranty. Contact your authorized Dri-Eaz
distributor for assistance.
WARNING! Check the Dragon 3600 for proper air-to-
fuel ratio before each use. Failure to adjust for
altitude changes could cause injury, permanent
damage to the unit and secondary damage when
ducting into a structure. It may also void the Dri-Eaz
warranty. Refer to "Adjusting for Altitude," p. 5, for
instructions.
WARNING! Breathing Hazard. Fuel exhaust contains
deadly carbon monoxide gas. Operate the Dragon
only outdoors in open area. NEVER operate indoors
or in enclosed spaces.
WARNING! Fire and Explosion Hazard
 Burner produces sparks and flame and unit
becomes hot during use.
 Keep away from flammable vapors, such as those
from gasoline, paint thinner or solvents.
49-120A 2014-12 Warranty 07-00424
Owner's Manual
Dragon 3600 Mobile Furnace
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA 98233
Phone: 800-932-3030 Fax: 360-757-7950 www.Dri-Eaz.com
Model F535-115V
 Keep away from combustible dusts, such as coal
dust or sawdust.
 Keep unit at least 8 ft. (2 m) away from any com-
bustible material.
 Keep children and pets away.
 Diesel fuel is flammable and can be explosive.
 Do not smoke while operating, servicing, or refueling
the Dragon.
 Before refueling, turn unit off, allow to cool and then
unplug.
 Hot surfaces can ignite fuel vapors.
WARNING! Electric Shock Hazard
 Connect to 115V power supply using either a 12/3 x
50 ft. (15 m) max or 10/3 100 ft. (30 m) max
extension cord.
 Unit must be grounded. Use only with 3-hole
grounded outlet.
 Never modify plug, extension cord or use an
adaptor.
 Never operate the unit in pooled or standing water. If
electrical components become wet, allow to dry
before using.
Product identification
An identification plate is attached to the side of the unit.
The plate shows the year of production, serial number,
electrical supply requirements, airflow, fuel capacity, and
a production code.
BEFORE YOU BEGIN
Warranty registration
Visit warranty.drieaz.com to register your purchase.
Registration allows us to better assist you with using,
maintaining or servicing your equipment and to contact
you in case we have important safety information
concerning your Dri-Eaz product. If you determine
service is required, have your equipment model, serial
number and original proof of purchase available and call
your distributor for assistance with obtaining a return
material authorization (RMA).
1
Dri-Eaz Products, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dragon 3600 F535 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dri-Eaz Dragon 3600 F535

  • Page 1 It may also void the Dri-Eaz warranty. Refer to “Adjusting for Altitude,” p. 5, for BEFORE YOU BEGIN instructions.
  • Page 2: Grounding Instructions

    Weather shield access panel. not shown) dial Handle Air intake Heated air outlet Control panel Fuel filter Fuel drain under and duct ring Fuel level sight tank (not shown) Fuel fill and cap 49-120A 2014-12 Warranty 07-00424 Dri-Eaz Products, Inc.
  • Page 3: Fuel Type

    WARNING: Failure to use diesel fuel as specified Setting up the Dragon could cause injury and permanent damage to the unit. It may also void the Dri-Eaz warranty. Choosing a location WARNING! Use the Dragon outdoors only. Place the For best results, purchase fresh fuel from a reliable fuel unit on a level, stable surface.
  • Page 4 NOTE: It is normal to see a small amount of smoke Power cord Control knob Temperature Thermostat when starting or stopping the unit. If smoke connection control knob sensor cable continues for more than a few seconds, turn of the 49-120A 2014-12 Warranty 07-00424 Dri-Eaz Products, Inc.
  • Page 5: Special Instructions

    7. The unit will resume normal operation. Replace the Access Plate. Fig. E: Air Adjustment Dial If unit will not reset after several attempts, contact your Loosen nut to Dri-Eaz distributor for assistance. adjust air flow. Adjusting for proper combustion and Dial rotation: altitude...
  • Page 6: Maintenance

    For parts and service contact your local distributor. you should Copies of the Dragon manual and related information  Make ducting runs as straight and short as are available at www.Dri-Eaz.com. Go to possible warranty.Dri-Eaz.com to register your purchase.  Keep the ducting unobstructed and free of...
  • Page 7 49-043 F 2011-06 Warranty 07-00424 Dri-Eaz Products, Inc.
  • Page 8 What Dri-Eaz Will Do: If a defect in materials or workmanship occurs within the warranty period, Dri-Eaz at its election, will repair or replace the defective part at no charge.
  • Page 9 Dri-Eaz realizará lo siguiente: Si se produce un defecto en los materiales o en la fabricación, dentro del período de la garantía, Dri-Eaz, a su criterio, reparará o reemplazará la pieza defectuosa sin costo alguno.