Relay plug (2 NC) DP1613 1 Preliminary note You will find instructions, technical data, approvals and further information using the QR code on the unit / packaging or at www.ifm.com. 1.1 Symbols used Requirement Instructions Reaction, result [...] Designation of keys, buttons or indications...
DP1613 Relay plug (2 NC) 2 Safety instructions • The unit described is a subcomponent for integration into a system. – The system architect is responsible for the safety of the system. – The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system.
Relay plug (2 NC) DP1613 3 Intended use The device is used for the electrically isolated switching of signals or currents. Control is via the 24 V digital inputs (IEC 61131 Type 3). The device has 2 outputs configured as normally closed (opto semiconductor relay).
DP1613 Relay plug (2 NC) 4 Installation ATTENTION Higher shock > IK06 w Damage possible w Protection rating and, in wet environments, electrical protection might be impaired u If necessary, the system creator must take external measures to protect the device depending on the requirements of the corresponding application.
Relay plug (2 NC) DP1613 5 Electrical connection The unit must be connected by a qualified electrician. u Observe the national and international regulations for the installation of electrical equipment. CAUTION Use in wet environments w Electric shock possible. u Voltage derating required (Ò Technical data).
DP1613 Relay plug (2 NC) CAUTION The output current is not limited. w No fire protection. w Risk of defect due to overload / short circuit. u Limit the output current. u Protect the circuit. Potential M12 socket ➁ Fuse...
Electrical connection (Ò / 7) Always use the provided connection cables to connect other devices. Information on matching Y cables, Y splitters and other accessories at www.ifm.com. 5.3.1 Mounting the connector The threaded connections in the device correspond to the M12 standard. To ensure compliance with the specified protection rating, only cables that comply with this standard may be used.
DP1613 Relay plug (2 NC) 6 Operation After power on, the device is ready for operation. It switches the outputs according to the incoming input signals.
Relay plug (2 NC) DP1613 7 Troubleshooting Error Root issue Troubleshooting The output does not switch Supply voltage too low at the input side Apply correct supply voltage at the input side No input signal Apply the input signal...
DP1613 Relay plug (2 NC) 8 Maintenance, repair and disposal The unit is maintenance-free. u It is not possible to repair the unit. u After use, dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations.