Download Print this page

Xylem CentriPro 9K585 Instruction Manual page 3

Moisture sensor relay

Advertisement

AQUAVAR SOLO, SOLO
Connections for Moisture Sensor (Part Number 9K585) for Balanced Flow, Aquavar SOLO, SOLO
3AB2, 5AB2; AB2 Controllers
Connect Black wire from Moisture Sensor to
transducer terminal marked "B" on controller.
WIRING 2 OR MORE MOISTURE SENSOR
RELAY IN SERIES
Connect Black and Red wires to the transducer
terminal. Connect the white wire from sensor 1 and
green wire from sensor 2 to the Run/Stop input
terminal. Then wire the green wire from sensor 1
to the white wire of sensor 2. Now these sensors
are wired in series. After all connections are made,
perform a test to ensure the drive turns off when
moisture is present at the sensors.
AND BALANCED FLOW
2
Connect Red wire
from Moisture
Sensor to transducer
terminal marked "R"
on controller.
Aquavar SOLO UIB Board
Transducer Block
B R W
G
Two Sensors
Sensor 1
Wire 2 Sensors in Series
and
2
Connect White and
Green wires from
Moisture Sensor to
the RUN/STOP INPUT
marked "JUMPER TO
RUN" on controller.
Run Stop / Input
W
G
Sensor 2
3

Advertisement

loading

This manual is also suitable for:

Centripro 9k584Centripro 9k583