Commissioning

7.
Commissioning
CAUTION
Danger due to electric current!
The setback input (ClimaCon F 90, F 100; terminal
4) and the change-over input (ClimaCon F 100,
F 310; terminal 5) are not potential-free.
!
Avoid direct contact.
!
Do not connect any equipment here that could
be damaged by electrical potentials or whose
function could be disturbed.
7.1

Establishment of the power supply

f
Establish the power supply.
Z
The room thermostat is now ready for operation.
7.2
ClimaCon F 210, F 310
Z
The display shows the currently measured
temperature. After approx. 5 seconds, the display
switches off.
7.2.1
ClimaCon F
A ClimaCon F room thermostat corresponds to a
room in the ClimaCon app.
1
Switch on the room thermostat (position
page 9).
2
Press the "Eco mode" and "Auto mode" keys
simultaneously for approx. 3 seconds (positions
8
in Fig. 6 on page 9).
Fig. 11:
ClimaCon F - Activation of the teach-in mode
Z
The "Eco mode" and "Auto mode" key flash alternately.
The display shows "BLu".
16
 
 
210, F
310 - Teach-in
1
in Fig. 6 on
The teach-in mode is active.
The teach-in mode remains active for approx.
1 minute. Without teach-in mode, the device
switches off and retains the previous settings.
3
Start the ClimaCon F app on your smartphone.
Fig. 12:
ClimaCon F app - Start screen
1
General information
2
"+" sign (teach-in of the room thermostat)
4
Tap the "+" sign to teach in a (further) room
thermostat.
7
and
Fig. 13:
ClimaCon F app - Start screen
1
Room
2
Symbol
5
Name the room in which the room thermostat is
operated.
1
IBy tapping the arrow (position
page 16), you have the possibility to make
the appropriate selection from a given list.
Alternatively, you can enter a desired text
manually.
2
1
2
1
in Fig. 13 on
115500984-V07.11.2022