INSTALLATION INSTRUCTIONS AND HOMEOWNER’S MANUAL Communicating Thermostat Model : R02P034 Printed in Canada on 2022-11-02 X00507 Rev.A 100% recycled paper...
Page 2
Do not touch The R02P034 is the full package in home control any spilled mercury. Wearing non- systems. absorbent gloves, clean up any spilled mercury and place it in a sealed container.
1 Installation This booklet contains installation instruction and information on the thermostat only. Separate installation instructions for the furnace or air handler and outdoor AC condensing unit or heat pump are provided. 1.1 Wiring Requirements Each communicating device in the system has a four wire connection labelled (R, C, 1, 2). Each R, C, 1, and 2 terminals must be wired consistently.
2.2 System Modes On/Off button allows to completely turn off the system. Then, no heating, cooling or ventilation command will be sent to the system. This button also allows to exit any settings menu. Fan Modes Press to switch between Fan On and Fan Auto. When the thermostat displays AUTO FAN, the circulating fan will run only when there is a heating or cooling demand.
Start is displayed indicating the start time of the current period is being set. Use to adjust the blinking parameter, and use to advance to the next one, in this order: 1. Period start time (hours) 2. Period start time (minutes) 3.
3 Thermostat Settings Press to access the settings menu. to change the parameter value. to move to next parameter and to move to the previous parameter. to exit to the main display. Item Description Range Defualt Note Temperature adjustment -6 to 6°C / -12 to 12°F 0°C / 0°F Min.
Page 10
4 Equipment User Menu Equipment operating information and options can be accessed by long pressing the button. to select the menu item, or to change the parameter value. to confirm the selection. to return to the upper menu. to exit to the main display. On entering this menu, you will have to select the equipment to be accessed.
Page 11
ST1 - Status 1 Code Parameter Indications Comments Main Limit Closed , Open Main limit control status MRLC Input Closed , Open Main reset limit control status HALC Input Closed , Open Heat assist limit control status IDM Output Off , Lo , Hi Inducer output status Furn Lo Pr Sw Closed , Open...
Page 12
- Unit Info Code Parameter Indications Comments Model Number XXXX-XXXXXXXXXXXXXXX Unit model number Serial Number XXXXXXXXXXXXXXXXXXX Unit serial number Software Vers XXXXXX Control software version - Setup Code Parameter Indications Comments Heat Rise Adjust 55F, 65F Adjust heat temperature rise Min Heat Adj % -15, -7, 0, 7, 15 Airflow adjustments at 40% firing rate Max Heat Adj %...
Page 13
Interface Board User Menus (Alizé) - Status Code Parameter Indications Comments Comp Speed XX Hz Compressor frequency Fan Speed XXX RPM Outdoor fan speed Coil Temp XX dF Indoor coil temperature (°F) Tube Temp XX dF Outdoor coil temperature (°F) Comp Temp XX dF Compressor discharge temperature (°F)