Download Print this page

Advertisement

Quick Links

包装盒内有什么?
随附的附件可能因产品而异。
包装盒上会显示随附于您产品的附件。
如何为产品充电?
1
3
2
1
2a
3a
4a
5
1
1 ×
2
3
2b
3b
4b
1
1
2
3
剃须
1
2
3
修剪
1
2
1
2
3
4
清洁修剪器
1
2
3
1
2
3
X500x_ZETA-X-CHINA_3000.084.8975.1_IID-SDFU-LFLT_foldedA7_BW.indd 1-4
X500x_ZETA-X-CHINA_3000.084.8975.1_IID-SDFU-LFLT_foldedA7_BW.indd 1-4
用水龙头清洁
1
2
3
1
2
3
4
5
6
7
8
彻底清洁
1
2
1x
1
1
2
3
3
4
5
1
6
7
8
9
10
11
12
1
2
刀头更换
1
2
1x
24
3
旅行锁
1
2
3
1
2
3
3
English
1
2
3
Important safety information
Only use the product for its intended purpose. Read
this important information carefully before you use
the product and its batteries and accessories, and save
it for future reference. Misuse can lead to hazards
or serious injuries. Accessories supplied may vary for
different products.
Warning
The supply unit is not included. To charge the
-
product, only use a supply unit that complies with
China GB standard GB4706.1-2005, 5 V
1 A, IPX4, in order to guarantee electrical safety.
We advise using Philips HQ87, or an equivalent
certified supply unit. To obtain HQ87, please
consult the Philips service hotline. Using a non-
certified supply unit may cause hazards or serious
injuries.
This shaver is waterproof (Fig. 2). It is suitable
-
for use in the bath or shower and for cleaning
under the tap. For safety reasons, the shaver can
therefore only be used without cord.
This appliance can be used by children aged from
-
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack
of experience and knowledge if they have been
given supervision or instruction concerning use of
the appliance in a safe way and understand the
hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall
not be made by children without supervision.
Do not modify the supply unit.
-
Do not use the supply unit in or near wall sockets
-
that contain an electric air freshener to prevent
irreparable damage to the supply unit.
2
Do not use a damaged appliance. Replace
-
damaged parts with new Philips parts.
Because of hygiene, only one person should use
-
the appliance.
Unplug the appliance before cleaning it with
-
water.
Only use cold or lukewarm water to clean the
-
appliance.
Never use compressed air, scouring pads, abrasive
-
cleaning agents or aggressive liquids to clean the
appliance.
Water may drip from the socket at the bottom of
-
the shaver when you rinse it. This is normal and
not dangerous because all electronics are enclosed
in a sealed power unit inside the shaver.
Only use original Philips accessories or
-
consumables.
Charge, use and store the product at a
-
temperature between 10 °C and 35 °C.
Keep product and batteries away from fire and
-
do not expose them to direct sunlight or high
temperatures.
If the product becomes abnormally hot or smelly,
-
changes color or if charging takes longer than
usual, stop using and charging the product and
contact Philips.
Do not place products and their batteries in
-
microwave ovens or on induction cookers.
Do not open, modify, pierce, damage or dismantle
-
the product or battery to prevent batteries
from heating up or releasing toxic or hazardous
substances. Do not short-circuit, overcharge or
reverse charge batteries.
If batteries are damaged or leaking, avoid contact
-
with the skin or eyes. If this occurs, immediately
rinse well with water and seek medical care.
Electromagnetic fields (EMF)
This Philips appliance complies with all applicable
standards and regulations regarding exposure to
electromagnetic fields.
Support
For all product support such as frequently asked
questions, please visit www.philips.com/support.
Recycling
This symbol means that electrical products and
-
batteries shall not be disposed of with normal
household waste (Fig. 3).
Follow your country's rules for the separate
-
collection of electrical products and batteries.
Troubleshooting
Problem
Possible cause
Solution
The
The appliance is
Unplug the
appliance
still connected to a
appliance and
does not
power source. For
press the on/off
work
safety reasons, the
button to switch
when I
appliance can only
on the appliance.
press the
be used without
on/off
cord.
button.
The rechargeable
Recharge the
battery is empty.
battery.
The travel lock is
Connect the
activated.
shaver to the
power outlet to
deactivate the
travel lock.
The shaving unit is
Clean the shaving
soiled or damaged
heads thoroughly
to such an extent
or replace them.
that the motor
cannot run.
X5001, X5002,
X5003, X5005,
X5009
, ≥
Problem
Possible cause
The appli-
Hairs or dirt
ance
obstruct the
does not
shaving heads.
shave as
well as it
used to.
The shaving heads
are damaged or
worn.
Water is
During cleaning,
leaking
water may collect
from the
between the inner
bottom
body and the
of the
outer shell of the
appliance.
appliance.
Removal of built-in rechargeable battery
The built-in rechargeable battery must only be
removed by a qualified professional when the
appliance is discarded. Before removing the battery,
make sure that the appliance is disconnected from the
wall socket and that the battery is completely empty.
Take any necessary safety precautions when
you handle tools to open the appliance and
when you dispose of the rechargeable battery.
When you handle batteries, make sure that
your hands, the product and the batteries are
dry.
To avoid accidental short-circuiting of batteries
after removal, do not let battery terminals
come into contact with metal objects (e.g.
coins, hairpins, rings). Do not wrap batteries in
aluminum foil. Tape battery terminals or put
batteries in a plastic bag before you discard
them.
Only remove the battery if it is completely
empty.
1 Pull the shaving unit off the shaver.
2 Use a flathead screwdriver to remove the top cap
of the housing.
3 Remove the screws.
4 Pull the inner parts out of the housing. If
necessary, use a pair of pliers.
5 Remove the rechargeable battery.
Solution
Clean the shaving
heads thoroughly.
Replace the
shaving heads.
This is normal and
not dangerous
because all
electronics are
enclosed in a
sealed power
unit inside the
appliance.
05-07-22 14:57
05-07-22 14:57

Advertisement

loading

Summary of Contents for Philips X5001

  • Page 1 China GB standard GB4706.1-2005, 5 V , ≥ 1 A, IPX4, in order to guarantee electrical safety. We advise using Philips HQ87, or an equivalent certified supply unit. To obtain HQ87, please consult the Philips service hotline. Using a non- certified supply unit may cause hazards or serious injuries.
  • Page 2 介于 10 °C 至 35 °C 之间。 5 取出充电电池。 请将产品和电池远离火源,切勿将 其暴露于阳光直射处或高温下。 如果产品异常发热或发出异味、变 色或充电时间比平时长,请停止使 用并停止为其充电,并联系飞利 浦。 切勿将产品及其电池放置在微波炉 中或电磁炉上。 为防止电池发热或释放有毒有害物 质,切勿打开、改装、刺穿、损坏 或拆卸产品或电池。 切勿使电池短 路、过度充电或反向充电。 如果电池损坏或出现泄漏,请避免 与皮肤或眼睛接触。 如果不慎接 触,请立即用清水冲洗并就医。 电磁场 (EMF) 本 Philips 产品符合所有有关暴露于电 磁场的适用标准和法规。 支持 有关常见问题等所有产品支持,请访问 www.philips.com/support。 X500x_ZETA-X-CHINA_3000.084.8975.1_IID-SDFU-LFLT_foldedA7_BW.indd 5-8 X500x_ZETA-X-CHINA_3000.084.8975.1_IID-SDFU-LFLT_foldedA7_BW.indd 5-8 05-07-22 14:57 05-07-22 14:57...

This manual is also suitable for:

X5002X5003X5005X5009