4.1.2 Tips for stable use

In order to use the PLC network stably, it is important to reduce the signal level attenuation of the
power line communication and reduce the noise level.

4.1.2.1 Signal attenuation due to transmission line resistance

Cause:
-
Long transmission path length
-
High impedance of the wire used
-
Power strip, filter, etc.
Corrective action example:
-
Add a multi-hop repeater on the transmission line,
and amplify the attenuated signal level.
-
Suppress line impedance.
Use wire with a large diameter
Reduction of line length, etc.
DA-PU100 Series Administrator's Manual