Control Panel Settings an Functions
The Jet model 197 control panels are designed to be used with several system
configurations. The primary selection of control panel operation is selected by
the array of DIP switches located at the top of the circuit board. Refer to the
following chart which outlines the function of the separate DIP switches and their
corresponding system controls:
Switch One *
Switch
Two *
Off
On
Off
On
Off
On
On
Switch Four
Switch Five
Switch Six
Off
On
Off
On
Switch Seven
Off
Single Aerator System
On
Dual Aerator System
Switch Eight
Off
Aerator 2 circuit high current sensing for Aerator
On
Aerator 2 circuit low current sensing for Compressor
Switch Nine
On/Off
* -
DIP switches one, two, and three will be fused in the ON position for 197
controls used with NSF Listed J-1500 series treatment systems which
must have continuous aeration
Jet Inc. 750 Alpha Drive Cleveland, OH 44143 www.jetincorp.com 800.321.6960
Aerator Timer Control
Switch
Three *
Off
Off
Off
Off
On
Off
On
Off
Off
On
Off
On
On
On
Auxiliary Output Control
Auxiliary Alarm Function
Off
All Outputs Inactive
Off
Output One Active
On
Outputs One and Two Active
On
All Outputs Active
Multiple Aerator Controls
Toggle multiple aeration alarm sensing
Toggle high/low current sensing
Test Mode Control
Toggle Test Mode
Aerator Run Time *
Continuous Run
On 50 min. / Off 10 min.
On 45 min. / Off 15 min.
On 40 min. / Off 20 min.
On 35 min. / Off 25 min.
On 30 min. / Off 30 min.
Continuous Run
Inactive