Troubleshooting Guide
Problem
No Power to Panel
Aerator Alarm After Start
Up
Auxiliary Alarm After Start
Up
No Power to Aerators
No Power to Pump
Auxiliary Outputs Inactive
Aerator Timer Not
Functioning
Aerator Reset Not
Functioning
Aerator Alarm with
Compressor
Alarms not Functioning
Jet Inc. 750 Alpha Drive Cleveland, OH 44143 www.jetincorp.com 800.321.6960
Probable Cause
•
No power from main
breaker panel
•
Internal panel power
switch in off position
•
Aerators not connected
and running
•
DIP aerator selection
incorrect
•
Aerator/Compressor
DIP setting incorrect
•
Alarm settings incorrect
(NO/NC)
•
Alarm or float condition
is active
•
Inbound power inactive
•
Timer setting in "Off"
cycle
•
Inbound power inactive
•
Alarm condition active
•
DIP settings incorrect
•
Excessive load on
external device
•
Incorrect DIP settings
•
External reset locked
out
•
External toggle not
contacting button
•
DIP not set to
compressor function
•
Automated reset
program active
(Normal Function)
- - 12 - -
Solution
•
Check wiring and
main breaker panel
•
Check on/off
switch
•
Check aerator(s)
and connections
•
Confirm DIP
settings are correct
for system design
•
Check alarm
setting jumpers for
proper NO/NC
•
Check external
devices and floats
•
Check connections
and main breaker
panel
•
Reset panel to
override "Off" cycle
•
Check connections
and main breaker
panel
•
Resolve alarm
conditions
•
Check DIP settings
•
Confirm power
requirements for
external device
•
Check DIP settings
•
Reset panel with
Master Reset
button
•
Adjust depth of
external toggle
•
Check DIP setting
•
Toggle test mode
"ON" if instant
alarms desired