TIG ASSEMBLY
TIG Welding
Insert the cable plug with the earth clamp into
the "+" socket on the front panel of the welding
machine, and tighten it clockwise.
Insert the cable plug of the TIG torch into the "-"
socket on the front panel of the machine and
tighten clockwise.
Fig 14
ON
AC230V
OFF
TIG Torch
29
Connect the TIG torch control switch into the
torch control outlet plug on the machine front
panel.
Connect the gas hose to the regulator /
flowmeter located on the shield gas cylinder and
connect the other end to the machine (Fig.14).
Panel
Remote
Gas
Hose
Earth Clamp
0.2
10
AMPS
PULSE HZ
200
200
1
0
POST GAS
DOWN
10
5S
ARC FORCE
SLOPE
TIG
Torch
control
switch