Fault
E:90-01 will light up
alternately.
E:92-40 will light up
alternately.
A different error code
appears in the display
window.
E:01-00 to E:90-10
Fault
Tableware is not dry.
Cause and troubleshooting
Mains voltage is too low.
This is not a fault on the appliance.
Contact an electrician.
1.
Have the mains voltage and electrical installation
2.
checked by an electrician.
Filters are soiled or blocked.
Clean the filters.
▶
→ "Cleaning filters", Page 41
A technical fault is present.
Press
.
1.
Unplug the appliance or switch off the fuse.
2.
Wait at least 2 minutes.
3.
Insert the mains plug of the appliance in a socket
4.
or switch on the fuse.
Switch the appliance on.
5.
If the problem occurs again:
6.
Press
.
‒
Turn off the water tap.
‒
Pull out the mains plug.
‒
Contact Customer Service → Page 57 and give
‒
the error code.
Cause and troubleshooting
No rinse aid used or dosage set too low.
Add Rinse aid → Page 26.
1.
Set the amount of rinse aid to be dispensed.
2.
→ "Setting the amount of rinse aid", Page 27
Programme or programme option has no drying
phase, or the drying phase is too brief.
Select a programme with drying, e.g. intensive,
▶
strong or ECO programme.
Some option buttons decrease the drying result, e.g
varioSpeed.
Water collects in recesses of the tableware or cutlery.
Troubleshooting aus
45