Repair Instruction
7.5.
Troubleshooting Tips
TS Tip #8
-
Water probe error, fault could be due to:
a. Water inside the boiler →
b. Probe reaches end of life →
c. Connection →
d. Power PCBA →
TS Tip #9
-
Published by Philips Consumer Lifestyle
Document No. : CSW-07-081-18028
Check wire continuity
Verify by using a new board
E-valve does not open when steam trigger is pressed:
a. If Iron LED keeps blinking, trigger press not detected, fault could be on:
Trigger mechanism or hose cord connection →
i)
Power PCBA and measure continuity between the black wire (pin1) and iron Neutral,
it should be short circuit when trigger is pressed, and open circuit when trigger is
released.
Power PCBA →
ii)
b. If Iron LED becomes steady on when press steam trigger, and system shows completed
Self-Check mode successfully after release the trigger →
Power PCBA
Remove water and retest
Replace Probe and retest
Verify by using a new board