Repair Instruction
7.5.
Troubleshooting Tips
TS Tip #1
-
-
-
-
TS Tip #2
-
Zero-crossing detection circuit error, Fault should be on PCBA
TS Tip #3
-
LEDs des not light up as specified, fault should be on one of the PCBAs or interconnection
TS Tip #4
-
Iron Temperature sensing circuit error, fault could be on:
a. Thermistor →
b.
c. Connection →
TS Tip #5
-
a. Power PCBA Check by test another board
TS Tip #6
-
Boiler temperature sensing circuit error, fault could be due to:
a. Thermistor →
b.
c. Connection →
TS Tip #7
-
Boiler heater power does not show in the power meter, fault could be due to:
a. Boiler is too Hot →
b. Boiler fuse or heating element Open Circuit →
c. Power PCBA →
Published by Philips Consumer Lifestyle
Document No. : CSW-07-081-18028
No Pumping sound, fault could be on:
a. Pump →
Check by apply AC voltage directly
b. Power PCBA →
Check by driving a known good pump
c. Connection →
Check wire continuity
No Buzzer Sound, fault could be on Power PCBA
Iron LED does not light up as specified, fault could be on:
a. Iron LED and hose cord wiring →
measure across pin 3 at female side and iron Neutral to check diode characteristics.
b. Power PCBA →
Verify by using a new board
Other LEDs does not light up as specified, fault could be on one of PCBAs or
interconnection
Check the resistance, should be around 200+kΩ
Power PCBA →
Verify by using a new board
Check wire continuity
Iron heater power does not show in the power meter, fault could be due to:
a. Iron is too hot →
Cool down and try again
b. Iron fuse or heating element Open Circuit →
Neutral Signal
Check the Resistance, should be around 200+KΩ
Power PCBA →
Verify by using a new board
Check Wire Continuity
Cool down and retry
Neutral Signal
Verify by using a new board
Disconnect connector 9016 from power PCBA and
Check Resistance between Iron Live and
Check resistance between Boiler Live and
For internal use only