Disassemble Instruction – Stand
WATER TANK ASSY 15
TRAY RUBBER CAP
STAND TOP ASSY 19
RETURN TUBE
INLET SUPPORT SEAL 30
INLET SUPPORT PLATE WELDED 31
INLET COUPLING SUPPORT 32
Remove
WATER TANK ASSY 15
Remove
Screw J1 to J3 (lift up Tray Rubber Cap)
Remove
Screw A1 to A6 & a1 to a2
Remove
STAND TOP ASSY 19
Remove
RETURN TUBE
Remove
Screw B1 to B2
Remove
INLET COUPLING SEAL
Remove
INLET COUPLING SUPPORT SEAL 30
Remove
TUBE
Remove
INLET SUPPORT PLATE WELDED 31
Remove
INLET COUPLING SUPPORT 32
POWER BOARD PCBA 20
PCBA HOLDER MOLDED 21
HALL SENSOR PCBA 22
INOX CLAMP 35
HOSE CLIP 34
PUMP MOUNTED ASSY 26
Remove
Screw C1 to C6
Remove
POWER BOARD PCBA 20
Remove
PCBA HOLDER MOLDED 21
Disconnect
All wire, Tubes & Hose
Remove
HALL SENSOR PCBA 22
Remove
INOX CLAMP 35
Remove
HOSE CLIP 34
Remove
PUMP MOUNTED ASSY 26
Published by Philips Consumer Lifestyle
Document No. : CSW-07-081-18028
SAFETY CAP 38B
SAFETY VALVE 38A
RINSE CAP ASSY 42
BOILER ASSY 36
SPACER BOTTOM
Remove
SAFETY CAP 38B
Remove
SAFETY VALVE 38A
Remove
E-VALVE 3
Remove
Screw D1 & D2
Remove
RINSE CAP ASSY 42
Remove
SPACER TOP
Remove
BOILER ASSY 36
Remove
SPACER BOTTOM
CLAMPING PLATE
HOSE CORD MOUNTED ASSY 14
UI BOARD PCBA 23
BUTTON FRAME PRTED 24
POWER BUTTON PRTED 25
STAND BOTTOM ASSY 50
Remove
Screw E1 & E2
Remove
CLAMPING PLATE
Remove
CORDSET 43
Remove
Screw F1 & F2
Remove
CORD CLAMP
Remove
HOSE CORD MOUNTED ASSY 14
Remove
Screw L1 to L3
Remove
UI BOARD PCBA 23
Remove
Light Guide
Remove
Screw M1 & M2
Remove
BUTTON FRAME PRTED 24
Remove
POWER BUTTON PRTED 25
Remove
STAND BOTTOM ASSY 50
For internal use only
Page 22 of 32
GC9610 – GC9650
E-VALVE 37
SPACER TOP
CORDSET 43
CORD CLAMP

Advertisement