Operating and
installation instructions
REMKO ELT series
Electric heater
ELT 9-6
This product is suitable only for well-insulated rooms or for occasional use.
Edition EN - Z08
Read the instructions prior to performing any task!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELT Series and is the answer not in the manual?

Questions and answers

Summary of Contents for REMKO ELT Series

  • Page 1 Operating and installation instructions REMKO ELT series Electric heater ELT 9-6 This product is suitable only for well-insulated rooms or for occasional use. Edition EN - Z08 Read the instructions prior to performing any task!
  • Page 3: Table Of Contents

    Contents Safety notes Unit description Commissioning Shutdown Care and maintenance Troubleshooting Intended use Customer service and guarantee Environmental protection and recycling Exploded view of the unit Spare parts list Maintenance protocol Technical data Electrical wiring diagram Carefully read this operating manual prior to commissioning / using the units! This operating manual is a translation of the German original.
  • Page 4: Safety Notes

    REMKO ELT Series Safety notes Unit description Always observe the respective local building code and fire prevention The units are portable electric heating units for industrial guidelines as well as the guidelines of the accident prevention and insurance associations when using the units.
  • Page 5: Commissioning

    Commissioning Operating sequence One person, who has been Heating adequately trained in the handling Depending on the respective of the units, should be tasked with The units operate in a fully operating modes, the units can the operation and monitoring of automatic manner subject to the be used for air heating or for air the units.
  • Page 6: Shutdown

    REMKO ELT Series Shutdown Care and maintenance Troubleshooting Regular care and observation The unit (fan) does not start. 1. Move the of some basic requirements will operating switch to ensure trouble-free operation and 1. Check the mains fuses on site.
  • Page 7: Intended Use

    “certificate of environment. structural design and equipment. guarantee” to REMKO GmbH & Our units are carefully packed The units must only be operated Co. KG at the time when the units...
  • Page 8: Exploded View Of The Unit

    REMKO ELT Series Exploded view of the unit Spare parts list Designation EDP no. Designation EDP no. Transport handle 1101142 Fan motor 1101094 Outer casing 1101098 Back wall 1101099 Exterior cladding (vers. INOX) 1111101 Thermostat assembly 1101066 Aftercooler thermostat 1104065...
  • Page 9: Maintenance Protocol

    ✍ Maintenance protocol Unit type: ........Unit number: ........10 11 12 13 14 15 16 17 18 19 20 Unit cleaned - outside - Unit cleaned - inside - Fan blade cleaned Protection grid cleaned Safety equipment checked Safety devices checked Unit checked for damage All fastening screws checked Electrical safety check...
  • Page 10: Technical Data

    REMKO ELT Series Technical data Series Symbol Unit ELT 9-6 (E) Nominal heating capacity Minimum heating power Maximum continuous heating power max,c Switchable heating capacity 2 x 4,5 Air volume Temperature increase (Δ t ) max. Power supply V/Hz 400/3~N/50 Max.
  • Page 11: Electrical Wiring Diagram

    Electrical wiring diagram Legend: = Contactor = Motor = Aftercooler thermostat R1 to R3 = Heating resistors for 1st Stage R4 to R6 = Heating resistors for 2nd Stage = Thermostat = Operating switch = Temperature limiter = Temperature limiter = Terminal block Switching level for operating switch [S] S 0 1 2 3...
  • Page 12 REMKO QUALITY WITH SYSTEMS Air-Conditioning | Heating | New Energies REMKO GmbH & Co. KG Telephone +49 (0) 5232 606-0 Hotline within Germany Telefax +49 (0) 5232 606-260 +49 (0) 5232 606-0 Klima- und Wärmetechnik Im Seelenkamp 12 E-mail info@remko.de...

This manual is also suitable for:

Elt 9-6

Table of Contents