REMKO ELT 10-HT Operation,Technology,Spare Parts
REMKO ELT 10-HT Operation,Technology,Spare Parts

REMKO ELT 10-HT Operation,Technology,Spare Parts

High temperature electric heater

Advertisement

Quick Links

REMKO ELT 10-HT
High temperature
Electric heater
Operation · Technology · Spare parts
Edition GB – J08

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELT 10-HT and is the answer not in the manual?

Questions and answers

Summary of Contents for REMKO ELT 10-HT

  • Page 1 REMKO ELT 10-HT High temperature Electric heater Operation · Technology · Spare parts Edition GB – J08...
  • Page 3: Table Of Contents

    Contents Unit description Safety notes Commissioning Shutdown Operation with a warm air hose Care and maintenance Troubleshooting Intended use Customer service and guarantee Environmental protection and recycling Electrical wiring diagram Maintenance protocol Exploded view of the unit Spare parts list Technical data Carefully read this operating manual prior to commissioning/using the units!
  • Page 4: Unit Description

    REMKO ELT 10-HT Unit description Safety notes The units are portable electric The units have been subjected The units must not be installed or ■ heating units for industrial to extensive material, functional operated in potentially flammable applications at various locations.
  • Page 5: Commissioning

    Commissioning One person, who has been Heating with a special Adjust the air outlet adequately trained in the handling purpose HT room thermostat temperature of the units, should be tasked with or duct thermostat (accessories) the operation and monitoring of the Upon start-up, set the fan speed to units.
  • Page 6: Shutdown

    ■ Only warm air hoses (accessories) water. that have been approved by e.g. pressure washers etc. Remko may be used as these have 1. Move the operating been designed specifically for these Never use abrasive or solvent- ■ switch to the “0”...
  • Page 7: Troubleshooting

    “Certificate of 3. Check the power plug. the basis of their structural design guarantee” to REMKO GmbH & and equipment. Co. KG at the time when the units 4. Check the operating switch.
  • Page 8: Electrical Wiring Diagram

    REMKO ELT 10-HT Electrical wiring diagram 400V/3~N/50Hz Fuse Fuse 6.3Amp KL:L1 L1 L2 L3 N PE 1 = Ventilation 2 = Heating 6×2.5 mm dT/80°C dT/100°C X2:1 EMV Filter EMC filter HT mode HT-Betrieb from 80°C ab 80°C 100°C Gelb...
  • Page 9: Maintenance Protocol

    ✍ Maintenance protocol Unit type: ........Unit number: ........10 11 12 13 14 15 16 17 18 19 20 Unit cleaned - outside - Unit cleaned - inside - Fan blade cleaned Protection grid cleaned Safety equipment checked Safety devices checked Unit checked for damage All fastening screws checked Electrical safety check...
  • Page 10: Exploded View Of The Unit

    REMKO ELT 10-HT Exploded view of the unit 3 (3a) We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
  • Page 11: Spare Parts List

    Grommet for mains cable Transport handle Reinforcement plate Fan with motor and protection grid Outer casing ELT 10-HT Outer casing ELT 10-HT INOX Condenser Front panel with outlet nozzle “RED” light (STB fault) Floor panel “GREEN” light (max. heating capacity) Front plate of floor panel “YELLOW”...
  • Page 12 REMKO, a partner who helps to solve problems. Sales REMKO offers not just a well established sales network both nationally and internationally, but also has exceptionally highly- qualified sales specialists. REMKO employees in the...