Operating and
installation instructions
REMKO ELT series
Electric heaters
ELT 2-1
This product is suitable only for well-insulated rooms or for occasional use.
Edition EN - Q03
Read the instructions prior to performing any task!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELT Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for REMKO ELT Series

  • Page 1 Operating and installation instructions REMKO ELT series Electric heaters ELT 2-1 This product is suitable only for well-insulated rooms or for occasional use. Edition EN - Q03 Read the instructions prior to performing any task!
  • Page 3: Table Of Contents

    Contents Safety notes Unit description Commissioning Shutdown Care and maintenance Troubleshooting Intended use Customer service and guarantee Environmental protection and recycling Exploded view of the unit Spare parts list Maintenance protocol Technical data Electrical wiring diagram Carefully read this operating manual prior to commissioning / using the unit! This operating manual is a translation of the German original.
  • Page 4: Safety Notes

    REMKO ELT series Safety notes Unit description Always observe the respective local building code and fire prevention The units are portable electric heating units for industrial guidelines as well as the guidelines of the accident prevention and insurance associations when using the units.
  • Page 5: Commissioning

    Commissioning Operating sequence One person, who has been Heating The units can be used in adequately trained in the handling the respective modes for air of the units, should be tasked with The unit operates in a fully heating and air circulation the operation and monitoring automatic manner subject purposes.
  • Page 6: Shutdown

    REMKO ELT series Shutdown Care and maintenance Troubleshooting Regular care and observation The unit (fan) does not start. 1. Move the operating of some basic requirements will switch to the "0" ensure trouble-free operation and 1. Check the mains fuses on site.
  • Page 7: Intended Use

    “certificate of environment. equipment. guarantee” to REMKO GmbH & Our units are carefully packed The units must only be operated Co. KG at the time when the units and delivered in sturdy transport by appropriately instructed are purchased and commissioned.
  • Page 8: Exploded View Of The Unit

    REMKO ELT series Exploded view of the unit We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
  • Page 9: Spare Parts List

    Spare parts list Designation EDP no. Transport handle 1103903 Outer casing 1103928 Aftercooler thermostat 1104065 Temperature limiter 1101161 Inner casing 1103931 Heating resistor 1103909 Front panel 1101063 Floor panel 1103932 Fan blade 1103819 Drive clutch 1103912 Fan motor 1103820 Back wall 1103915 Power cable with plug 1101320...
  • Page 10: Maintenance Protocol

    REMKO ELT series ✍ Maintenance protocol Unit type: ........Unit number: ........10 11 12 13 14 15 16 17 18 19 20 Unit cleaned - outside - Unit cleaned - inside - Fan blade cleaned Protection grid cleaned Safety equipment checked...
  • Page 11: Technical Data

    Technical data Series Symbol Unit ELT 2-1 Nominal heat capacity Minimum heating power Maximum continuous heating power max,c Switchable heating capacity Air volume Air outlet temperature °C Power supply V/Hz 230/1~/50 Max. rated current Max. power consumption 2,25 Auxiliary current consumption at nominal heating power Auxiliary current consumption at minimum heating power...
  • Page 12 REMKO QUALITY WITH SYSTEMS Air-Conditioning | Heating | New Energies REMKO GmbH & Co. KG Telephone +49 (0) 5232 606-0 Hotline within Germany Klima- und Wärmetechnik Telefax +49 (0) 5232 606-260 +49 (0) 5232 606-0 Im Seelenkamp 12 E-mail info@remko.de...