Page 1
Operating manual REMKO EM series Electric heating units EM 6000, EM 10000, EM 18000 This product is suitable only for well-insulated rooms or for occasional use. Edition N-06 - 1, en_GB Read the instructions prior to performing any task!
Contents Safety notes Unit description Commissioning Shutdown Care and maintenance Troubleshooting Intended use Customer service and guarantee Environmental protection and recycling Exploded view of the unit Spare parts list Maintenance log Technical data Electrical wiring diagram 13-14 Carefully read this original operating manual prior to commissioning / using the units! This operating manual is a translation of the German original.
REMKO EM series Safety notes Unit description Always observe the respective local building code and fire prevention The units are portable electric heating units for industrial guidelines as well as the guidelines of the accident prevention and insurance associations when using the units.
Commissioning Operating sequence One person, who has been Heating adequately trained in the handling The units can be used according of the units, should be tasked with The units operate in a fully to the relevant operating modes the operation and monitoring automatic manner subject for air heating or simply for air of the units.
REMKO EM series Shutdown Care and maintenance Troubleshooting Regular care and observation The unit (fan) does not start. 1. Move the operating of some basic requirements will switch to ensure trouble-free operation and 1. Check the mains fuses on site.
Our units are carefully packed “Certificate of guarantee” The units must only be operated to REMKO GmbH & Co. KG and delivered in sturdy transport by appropriately instructed at the time when the units are packaging made from cardboard personnel.
REMKO EM series Exploded view of the unit EM 6000 EM 10000 We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
Page 9
EM 18000 We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
REMKO EM series Spare parts list Designation EM 6000 EM 10000 EM 18000 EDP no. EDP no. EDP no. Transport handle 1111973 1111973 1111973 Exterior cladding 1111974 1103957 1108002 Aftercooler thermostat 1104065 1104065 1104065 77 °C thermal cut-out 1101161 1101161...
REMKO EM series Technical data Series Symbol Unit EM 6000 EM 10000 EM 18000 Nominal heat capacity 10.0 18.0 Minimum heat capacity Maximum continuous 10.0 18.0 max,c heating power Switchable heating capacity 2 x 3.0 2 x 5.0 3 x 6.0...
Electrical wiring diagram for EM 6000, EM 10000 400V/3~N/50Hz L1 L2 L3 N 06.2018 Legend: = Heating resistor = Connection terminal strip Switching level for = Contactor operating switch [S] = Fan motor = Aftercooler thermostat HW1-3 = Heating resistors, 1st stage HW4-6 = Heating resistors, 2nd stage = Room thermostat...
Page 14
REMKO EM series Electrical wiring diagram for EM 18000 400V/3~N/50Hz L1 L2 L3 N 06.2018 Legend: = Heating resistor Switching level for operating switch [S] = Connection terminal strip = Contactor 1 2 3 4 = Fan motor = Aftercooler thermostat...
Page 16
REMKO, a partner who helps to solve problems. Sales REMKO offers not just a well established sales network both nationally and internationally, but also has exceptionally highly- qualified sales specialists. REMKO employees in the field are...