ERROR
MOTOR LOCKED
8
ERROR
POWER
9
FAILURE
DRY HEATER
10
ERROR
SUPPLIED
11
VOLTAGE IS NOT
CORRECT
NFC MODULE
12
ERROR
NFC VERSION
13
ERROR
NOTE
When you paused the machine under drying cycle, drying fan motor can be operated to save itself for 30
seconds. And then the machine displays "
SYMPTOM
• The connector in the LEAD WIRE ASSEMBLY is
not connected to the connector of STATOR
ASSEMBLY.
• The hall sensor is out of order/defective.
• The washer experienced a power failure
• The Dry Heater is out of order
• The Connector of the Dry Heater is not connected
properly to the cinnector in the Main PWB ASSEMBLY
• The Dry fan motor is out of order
• Supplied voltage and rated voltage are not matched.
• The connector in the DISPLAY PCB ASSEMBLY is
not connected to the connector of NFC PCB
ASSEMBLY.
• The NFC HARNESS between the NFC PCB
ASSEMBLY and DISPLAY PCB ASSEMBLY is cut
(open circuited).
• The NFC PCB ASSEMBLY is out of order/defective.
* nC is displayed only in the first screen of the Load
Test Mode.
• NFC version is not matched.
• nU is displayed only in the first screen of the Load
Test Mode.
" on the panel.
27
CAUSE
Reconnect or repair the connector.
Replace the STATOR ASSEMBLY
Press the start/pause button
Reconnect or repair the connector.
Replace the DISPLAY PCB ASSEMBLY.
Replace the NFC PCB ASSEMBLY.
Replace the NFC PCB ASSEMBLY.