Truper BOPA-1/2 Manual
Truper BOPA-1/2 Manual

Truper BOPA-1/2 Manual

Self-priming peripheral water pump

Advertisement

Quick Links

Manual
Self-priming
Peripheral
Water Pump
Applies for:
Models
BOPA-1/2
BOPA-3/4
BOPA-1
BOPA-1/2
BOPA-3/4
BOPA-1
CAUTION
Codes
12780
12781
12782
Read the user's manual thoroughly
before operating this tool.
For agriculture

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BOPA-1/2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Truper BOPA-1/2

  • Page 1 Manual Self-priming Peripheral For agriculture Water Pump Applies for: Models Codes BOPA-1/2 12780 BOPA-3/4 12781 BOPA-1 12782 BOPA-1/2 BOPA-3/4 BOPA-1 Read the user’s manual thoroughly CAUTION before operating this tool.
  • Page 2: Table Of Contents

    Installation Keep this manual for future references. Start Up The illustrations in this manual are for reference Maintenance only. They might be different from the real tool. Troubleshooting Notes Authorized Service Centers Warranty Policy BOPA-1/2 BOPA-3/4 BOPA-1 ENGLISH...
  • Page 3: Technical Data

    Technical Data BOPA-1/2 BOPA-3/4 BOPA-1 Code 12780 12781 12782 Description Self-priming peripheral water pump Voltage 127 V Frequency 60 Hz Speed 3450 RPM Current 11 A Power 1/2 Hp 3/4 Hp 1 Hp Outlet and Inlet Diameter 1” -11,5 NPT...
  • Page 4: General Power Tool Safety Warnings

    General power tool safety warnings WARNING! Read carefully all safety warnings and instruction listed below. Failure to comply with any of these warnings may result in electric shock, fire and / or severe damage. Save all warnings and instructions for future references.
  • Page 5: Safety Warnings For Using Water Pumps

    Safety Warnings for Using Water Pumps CAUTION • Do not install the pump outdoors or Adequate use near wet areas. WARNING • Do not install the pump in areas where • The pump is a stationary device designed to pump clean, neutral liquids with no abrasive solids suspended;...
  • Page 6: Installation

    Installation Mounting • The pump shall be installed in a dry place sheltered from outdoor weather but that allows the flow of air for its adequate ventilation (A). Ambient temperature shall not exceed 104 °F. • Use bolts to fix the pump into a concrete base to avoid vibration (B).
  • Page 7: Start Up

    Installation Electric Connection • Call a professional electrician to set up the electric connections to the power source (G), meeting the mandatory directives. • The fixed installation shall incorporate a device that assure the omnipolar connection of energy. • Make sure the electric requirements described in this Manual and in the pump nameplate match the power supply capacity values.
  • Page 8: Maintenance

    Maintenance • The pump is maintenance free only if the following cautions are followed: • If there is risk of freezing empty the pump completely removing the drain cap (J). Remember to purge the pump before starting up again. • Check the foot valve (not included) regularly and clean it if necessary.
  • Page 9: Troubleshooting

    Troubleshooting Problem Cause Solution The motor does not • There is no power. • Check the connection and voltage values. start. • Stuck impeller. • Release it with a screwdriver (see page 8). The motor is turning • Clogged foot valve filter. •...
  • Page 10: Notes

    Notes ENGLISH...
  • Page 11: Authorized Service Centers

    Authorized Service Centers In the event of any problem contacting a Service Center, please see our webpage www.truper.com to get an updated list, or call our toll-free numbers 800 690-6990 or 800 018-7873 to get information about the nearest Authorized Service Center.
  • Page 12: Warranty Policy

    . For questions or comments, call 800-690-6990. Imported by: Truper, S.A. de C.V. Parque Industrial #1, Jilotepec, Edo. de Méx., Méx. C.P. 54240. Made in China. Stamp of the business: Delivery date: www.truper.com...