Bosch rexroth CS660 Calibration Manual page 10

Spreader controller
Hide thumbs Also See for rexroth CS660:
Table of Contents

Advertisement

Auto Nulling
1.
Press "Start" to begin. This procedure will automatically ramp up the conveyor motor speed and then
ramp down to capture the both "Min" and "Max" speed values and storing them as a saved calibration.
Note: This feature can only be used with motors with speed sensor. It takes about 30~60s to complete.
2.
Calibrated values will be shown in the Min output & Max output text boxes
3.
Please check the "Min" null value to verify it is minimum. (< 5RPM). Do this by pressing on the Min
output value (conveyor will start to turn). Press again to stop.
Manual Nulling
1. Press "Min" value field to pop up the UP/DN arrows and enter into edit mode.
2.
Use up and down arrows to adjust speed so that the motor just begins to turn
3.
Press the "Min" value field again to end the edit mode and accept the value
4.
Do the same for "Max" to adjust the motor to a safe max speed or until the RRM readout stops to
increase.
5.
Forward Gain and Blast settings can also be adjusted
Bosch Rexroth Canada I March 2021 ı Revision 3.0