Luxaire ACCLIMATE Series Technical Manual page 8

2-stage split system heat pumps 19 seer - r-410a - 1 phase 2 thru 5 nominal tons
Table of Contents

Advertisement

5490689-LTG-F-0620
SYSTEM CAPACITY - Single Piece and Modular Air Handlers (Continued)
AIR HANDLER
UNIT
MODEL
MODEL
WIDTH
HL19B3621S
MVC20DN21
HL19B3621S
MVC20DN21
HL19B3621S
MVC20DN21
HL19B3621S
MVC20DN21
HL19B3621S
MVC20DN21
HL19B3621S
MVC20DN21
HL19B4821S
AE60DX21
HL19B4821S
AE60DX21
HL19B4821S
AVC60DX21
HL19B4821S
AVC60DX21
HL19B4821S
ME20DN21
HL19B4821S
ME20DN21
HL19B6021S
AE60DX21
HL19B6021S
AE60DX21
HL19B6021S
AVC60DX21
HL19B6021S
AVC60DX21
HL19B6021S
ME20DN21
HL19B6021S
ME20DN21
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
1. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
3. Heating MBH based on AHRI standards of 70°F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
COP (Coefficient of Performance) equals Heating MBH output divided by (total KW input x 3.412).
— = Not applicable.
8
COIL
RATED
Stage
1
MODEL
CFM
24.5
CF/CM42D
1
24.5
CF/CM42D
2
1175
24.5
CF/CM48D
1
24.5
CF/CM48D
2
1175
24.5
CF/CM60D
1
24.5
CF/CM60D
2
1175
24.5
1
1200
24.5
2
1375
24.5
1
1075
24.5
2
1400
24.5
CF/CM64D
1
1300
24.5
CF/CM64D
2
1475
24.5
1
1375
24.5
2
1550
24.5
1
1050
24.5
2
1600
24.5
CF/CM64D
1
1325
24.5
CF/CM64D
2
1675
2
COOLING
NET MBH
SEER
TOTAL
SENS.
825
29.6
21.8
18.00
35.4
28.2
825
29.6
21.8
18.00
35.4
28.2
825
30.0
22.0
19.00
36.0
28.4
38.0
29.4
17.00
46.5
34.8
37.6
28.0
17.00
46.5
35.2
38.5
30.8
17.00
47.0
36.2
42.5
31.8
16.50
56.5
41.0
41.0
27.8
16.50
56.5
41.0
42.5
31.2
16.50
57.0
42.5
HEATING
NET MBH
EER
HSPF IV
47°F OD 17°F OD
27.00
28.80
13.00
35.60
21.80
9.00
27.40
24.20
14.00
35.20
21.80
9.60
27.80
24.40
14.00
36.00
22.40
9.60
24.15
30.60
13.00
46.50
30.40
9.60
24.55
30.40
13.00
46.50
30.60
9.60
24.10
30.60
13.00
46.50
30.40
9.60
20.70
37.40
13.00
57.50
36.40
9.60
21.00
37.00
12.50
57.50
37.00
9.60
21.30
37.20
13.00
57.50
36.60
9.60
Johnson Controls Unitary Products
3
COP
HSPF V
47°F OD 17°F OD
3.30
8.05
3.44
2.68
3.80
8.25
4.10
2.68
3.24
8.35
3.72
2.82
3.72
8.65
4.06
2.98
3.66
8.55
4.02
2.94
3.78
8.70
4.10
3.00
3.68
8.15
3.86
2.62
3.50
8.35
3.82
2.72
3.70
8.50
3.92
2.76