Physical And Electrical Data; Dimensions - Luxaire ACCLIMATE Series Technical Manual

2-stage split system heat pumps 19 seer - r-410a - 1 phase 2 thru 5 nominal tons
Table of Contents

Advertisement

PHYSICAL AND ELECTRICAL DATA

MODEL
Unit Supply Voltage
1
Normal Voltage Range
Minimum Circuit Ampacity
Max. Overcurrent Device Amps
Min. Overcurrent Device Amps
Compressor
Crankcase Heater
Factory External Discharge Muffler
HS Kit Required with TXV
HS Kit Part Number (S1-2SA067*****)
Fan Diameter Inches
Fan Motor (ECM)
Coil
Liquid Line Set OD (Field Installed)
Vapor Line Set OD (Field Installed)
6
Unit Charge (Lbs. - Oz.)
Charge Per Foot, Oz.
Operating Weight Lbs.
Note: These models are shipped with a Hard Start Kit installed at the factory.
1. Rated in accordance with AHRI Standard 110-2012, utilization range "A".
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. Use S1-2SA067***** series kit. See Hard Start Kit Accessory Installation Manual.
5. For applications with non-standard vapor line sizes, see the "Applications & Accessories" section of this Technical Guide.
6. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or sub-
tract the amount of refrigerant, using the difference in actual lineset length (not the equivalent length) multiplied by the per foot value.
‡ Adapter fitting must be field installed for the required 1-1/8" line set.
Johnson Controls Unitary Products
2
3
Type
Rated Load
Locked Rotor
4
Rated HP
Rated Load Amps
Nominal RPM
Nominal CFM
Face Area Sq. Ft.
Rows Deep
Fins / Inch
5
HL19B2421S
HL19B3621S
208-230V, 1 60Hz
15.30
21.4
25
35
20
25
2-Stage Scroll
2-Stage Scroll
10.0
14.9
62.9
84.2
Yes
Yes
Yes
Yes
No
No
10106
10106
24
26
1/3
1/3
2.80
2.80
640
830
2500
4000
23.05
26.4
1
2
22
18
3/8
3/8
3/4
3/4
6 - 1
12 - 7
0.62
0.62
215
285

DIMENSIONS

Unit
Model
HL19B2421S
40-1/4
HL19B3621S
40-1/4
HL19B4821S
46-1/2
HL19B6021S
46-1/2
‡ Adapter fitting must be field installed for the required 1-1/8" line set.
All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of base pan to top of fan guard.
Overall length and width include screw heads.
5490689-LTG-F-0620
HL19B4821S
187 to 252
28.2
45
30
2-Stage Scroll
20.4
122.1
Yes
Yes
No
10106
26
1/3
2.80
830
4100
31.2
2
18
3/8
7/8
17 - 7
0.67
315
Dimensions
Refrigerant Connection
(Inches)
Service Valve Size
A
B
C
Liquid
35-1/2
32
38-1/4
34-1/2
3/8
38-1/4
34-1/2
38-1/4
34-1/2
HL19B6021S
31.4
50
35
2-Stage Scroll
22.9
147.2
Yes
Yes
No
10106
26
1/3
2.80
830
4100
31.2
2
18
3/8
1-1/8
18 - 10
0.75
315
Vapor
3/4
7/8
7/8
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hl19b24Hl19b2421sHl19b3621sHl19b4821sHl19b6021s

Table of Contents