DESCRIPTION
The heat pump condensing unit is the outdoor part of a versatile
system of heating and air conditioning. It is designed to be cus-
tom-matched with one of UPG's complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal appli-
cations to provide a complete system. Electric Heaters are
available, if required. Add-on coils are available for use with
upflow, downflow, or horizontal furnaces and air handlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed of
copper tubing and enhanced aluminum fins for increased
efficiency and corrosion protection.
• PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure, temperature, and
externally by a factory installed high pressure switch. This is
accomplished by the simultaneous operation of high pres-
sure relief valve and a temperature sensor which protects the
compressor if undesirable operating conditions occur. A liq-
uid line filter-drier further protects the compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted fan
is blown up away from the structure and any landscaping.
This allows compact location on multi-unit applications.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living area.
The rigid top panel effectively isolates any motor sound. Iso-
lator mounted compressor and the rippled fins of the con-
denser coil muffle the normal fan motor and compressor
operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, and a single panel covering the electrical controls
make for easy servicing of the unit.
ISO 9001
Certified Quality
• SECURED SERVICE VALVES - Secured re-usable service
Management System
valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
• Agency Listed - U.L. and C.U.L. listed - approved for out-
door application. The unit is certified in accordance with the
Unitary Small Equipment cerification program, which is
based on ARI Standard 210/240.
445073-LTG-A-0109

Advertisement

loading

Summary of Contents for Luxaire THRD18S41S1

  • Page 1 445073-LTG-A-0109 DESCRIPTION The heat pump condensing unit is the outdoor part of a versatile system of heating and air conditioning. It is designed to be cus- tom-matched with one of UPG’s complete line of evaporator sections, with each serving a specific function. Matching Air Handlers are available for upflow, downflow, or horizontal appli- cations to provide a complete system.
  • Page 2 445073-LTG-A-0109 Physical and Electrical Data THRD18 THRD24 THRD30 THRD36 THRD42 THRD48 THRD60 MODEL S41S1 S41S1 S41S1 S41S1 S41S1 S41S1 S41S1 Unit Supply Voltage 208-230V, 1 60Hz 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 11.2 12.4 14.9 19.9 21.1 23.0 35.4 Max.
  • Page 3 445073-LTG-A-0109 Additional R-410A Charge / Orifice Size for Various Matched Systems Outdoor Unit THRD18S41S1 THRD24S41S1 THRD30S41S1 THRD36S41S1 THRD42S41S1 THRD48S41S1 THRD60S41S1 .049/902/4F1 .055/903/4G1 .060/903/4G1 .067/904/4H1 .075/905/4J1 .078,.081/906/4K1 906/4K1 Required Orifice or TXV Factory Charge, lbs-oz 5 - 6 5 - 8...
  • Page 4 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING UNIT COIL RATED NET MBH MODEL SEER MODEL MODEL TOTAL SENS. 13 SEER HP WITH MV - VARIABLE SPEED THRD18S41S1 MV12B FC/MC18B 18.0 13.5 13.00 11.20 THRD18S41S1 MV12B FC/MC24B 18.0 13.5 13.00 11.45...
  • Page 5 13 SEER HP WITH VARIABLE SPEED FURNACES L*(8,L)C*A12 FC/MC/PC/UC24A 18.0 13.5 13.00 11.00 L*(8,L)C*B12 FC/MC/PC/UC24B 18.0 13.5 13.00 11.00 L*9C*B12 FC/MC/PC/UC24B 18.0 13.5 13.00 11.00 THRD18S41S1 L*(8,L)C*A12 FC/MC/PC/UC30A 18.0 13.5 13.00 11.00 L*(8,L)C*B12 FC/MC/PC/UC30B 18.0 13.5 13.00 11.00 L*9C*B12 FC/MC/PC/UC30B 18.0 13.5 13.00 11.00...
  • Page 6 445073-LTG-A-0109 HEATING PERFORMANCE - With Air Handler ARI HEATING UNIT COIL 47F 17F HSPF MODEL HANDLER MODEL 13 SEER HP WITH MV - VARIABLE SPEED THRD18S41S1 MV12B FC/MC18B 17.6 3.36 1.43 2.28 1.14 7.70 THRD18S41S1 MV12B FC/MC24B 17.6 3.36 1.43 2.28...
  • Page 7 1.43 2.28 1.14 7.70 L*(8,L)C*B12 FC/MC/PC/UC24B 17.6 3.36 1.43 2.28 1.14 7.70 L*9C*B12 FC/MC/PC/UC24B 17.6 3.36 1.43 2.28 1.14 7.70 THRD18S41S1 L*(8,L)C*A12 FC/MC/PC/UC30A 17.6 3.36 1.43 2.28 1.14 7.70 L*(8,L)C*B12 FC/MC/PC/UC30B 17.6 3.36 1.43 2.28 1.14 7.70 L*9C*B12 FC/MC/PC/UC30B 17.6 3.36...
  • Page 8: Sound Power Ratings

    445073-LTG-A-0109 HEATING CAPACITY - With Variable Speed Furnaces (Continued) ARI HEATING VARIABLE UNIT COIL SPEED 47F 17F HSPF MODEL MODEL FURNACE 13 SEER HP WITH VARIABLE SPEED FURNACES L*(8,L)C*C16 FC/MC/PC/UC48C 40.0 3.95 2.64 23.4 2.76 2.17 8.75 L*9C*C16 FC/MC/PC/UC48C 40.0 3.95 2.64 23.4...
  • Page 9: Typical Installation

    445073-LTG-A-0109 TYPICAL INSTALLATION MINIMUM 24” SERVICE ACCESS CLEARANCE THERMOSTAT 48” OVERHEAD ON ONE SIDE CLEARANCE WEATHERPROOF DISCONNECT SWITCH NEC CLASS 1 WIRING 10” CLEARANCE TO FURNACE OR AROUND PERIMETER AIR HANDLER TERMINAL BLOCK NEC CLASS 2 WIRING TO INDOOR COIL NOTE: ALL OUTDOOR WIRING CONTROL...
  • Page 10 445073-LTG-A-0109 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. THRD18S41S1 INDOOR COIL MODEL NO. F6FP18 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 18.1 19.9 20.3 22.0 23.3 19.9 21.2 21.3 22.8 23.9 21.8 22.5 22.4 23.5 24.6...
  • Page 11 445073-LTG-A-0109 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. THRD24S41S1 INDOOR COIL MODEL NO. F6FP24 IDCFM 1000 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 24.4 26.0 26.9 29.5 30.7 26.4 26.3 28.0 30.4 31.4 28.4 26.5 29.0 31.4 32.0 S.C.
  • Page 12 445073-LTG-A-0109 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. THRD30S41S1 INDOOR COIL MODEL NO. F6FP30 IDCFM 1000 1200 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 29.7 32.9 32.9 35.3 38.2 31.8 33.6 33.9 36.4 39.1 33.9 34.4 34.8 37.5 40.0...
  • Page 13 445073-LTG-A-0109 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. THRD36S41S1 INDOOR COIL MODEL NO. F6FP36 IDCFM 1000 1200 1400 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 35.0 37.8 37.8 41.8 46.1 37.3 39.1 39.1 43.1 47.3 39.5 40.5 40.5 44.4...
  • Page 14 445073-LTG-A-0109 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. THRD42S41S1 INDOOR COIL MODEL NO. F6FP42 IDCFM 1200 1400 1600 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 43.1 45.7 46.2 51.4 56.6 45.5 46.9 47.2 52.7 57.8 47.9 48.0 48.2 54.0...
  • Page 15 445073-LTG-A-0109 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. THRD48S41S1 INDOOR COIL MODEL NO. F6FP48 IDCFM 1400 1600 1800 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 48.9 52.7 52.5 58.0 62.8 50.9 53.6 53.6 59.0 64.0 52.9 54.6 54.8 60.0...
  • Page 16 445073-LTG-A-0109 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. THRD60S41S1 INDOOR COIL MODEL NO. FC/MC62 IDCFM 1400 1600 1800 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 54.0 57.1 56.9 62.3 67.6 56.0 57.9 57.8 63.4 69.1 58.0 58.7 58.7 64.4...
  • Page 17 445073-LTG-A-0109 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO THRD18S41S1 EVAPORATOR COIL MODEL NO F6FP18 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 22.0 23.6 25.3 20.6 22.2 23.7 19.2 20.7 22.2...
  • Page 18 445073-LTG-A-0109 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO THRD24S41S1 EVAPORATOR COIL MODEL NO F6FP24 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 27.6 28.9 30.2 25.9 27.2 28.5 24.1 25.5 26.8 22.7...
  • Page 19 445073-LTG-A-0109 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO THRD30S41S1 EVAPORATOR COIL MODEL NO F6FP30 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 1200 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 33.1 31.7 30.2 31.6 31.4 31.1 30.1 31.1 32.1...
  • Page 20 445073-LTG-A-0109 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO THRD36S41S1 EVAPORATOR COIL MODEL NO F6FP36 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 1200 1400 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 46.1 47.6 49.0 44.0 45.5 46.9 42.0 43.3...
  • Page 21 445073-LTG-A-0109 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO THRD42S41S1 EVAPORATOR COIL MODEL NO F6FP42 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1200 1400 1600 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 47.6 47.5 47.5 46.0 46.4 46.7 44.4 45.2...
  • Page 22 445073-LTG-A-0109 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO THRD48S41S1 EVAPORATOR COIL MODEL NO F6FP48 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1400 1600 1800 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 54.5 53.4 52.4 53.4 53.5 53.6 52.4 53.6...
  • Page 23 445073-LTG-A-0109 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO THRD60S41S1 EVAPORATOR COIL MODEL NO FC/MC62 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1600 1800 2000 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 65.7 66.7 67.6 64.7 65.4 66.1 63.8 64.1...
  • Page 24 NOTES Subject to change without notice. Printed in U.S.A. 445073-LTG-A-0109 Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: Nothing Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069...