Miele PUR 98 D Operating And Installation Instructions

Miele PUR 98 D Operating And Installation Instructions

Ventilation system

Advertisement

Quick Links

Operating and Installation
Instructions
Ventilation System
To prevent accidents and damage to the appliance, you must read
these instructions before installing the appliance and using it for the
first time.
en-US
M.-Nr. 12 254 070

Advertisement

Table of Contents
loading

Summary of Contents for Miele PUR 98 D

  • Page 1 Operating and Installation Instructions Ventilation System To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 12 254 070...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS ............Caring for the environment ................11 Guide to the ventilation hood ................12 Description of functions ................... 14 Operation......................15 Turning on the blower..................15 Selecting the power level ..................15 Delayed shut-down ..................... 15 Turning off the blower..................
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
  • Page 4  Unauthorized installation, maintenance, and repairs can cause considerable danger for the user. Installation, maintenance, and repairs must only be carried out by a Miele authorized technician.  A damaged ventilation hood can be dangerous. Always check for visible signs of damage. Never use a damaged ventilation hood.
  • Page 5 The function and operation of the protective measures provided in the domestic electrical installation and in this Miele product must also be maintained in isolated operation or in operation that is not synchronized with the grid power supply, or these measures must be replaced by equivalent measures in the installation.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS  Only open the housing as described in the enclosed “Installation diagram” and in the “Cleaning and care” section of this manual. Under no circumstances should any other parts of the housing be opened. Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults.
  • Page 7 IMPORTANT SAFETY INSTRUCTIONS  Open flames are a fire hazard. The use of an open flame under the ventilation hood is not permitted. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the ventilation hood could draw flames into the filter.
  • Page 8 IMPORTANT SAFETY INSTRUCTIONS  Always turn the ventilation hood on whenever a burner is in use to prevent damage from condensation.  Overheated oil and fat can ignite, causing fire damage to the ventilation hood. Do not leave cookware, pans, and deep-fat fryers unattended when cooking with oil or fat.
  • Page 9 IMPORTANT SAFETY INSTRUCTIONS Proper installation  WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: - a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Page 10 The steam can reach the electrical components and cause a short circuit. Accessories and parts  Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty may become void.  Defective components should be replaced by Miele original parts only.
  • Page 11: Caring For The Environment

    Consult with local authorities, dealers or Miele in order to dispose of and recycle electrical and electronic appliances. Miele assumes no responsibility for deleting any personal data left on the appliance being disposed.
  • Page 12: Guide To The Ventilation Hood

    Guide to the ventilation hood...
  • Page 13 Guide to the ventilation hood a Telescopic extension piece b Duct cover c Canopy d Controls e Grease filter f Spacer frame The spacer frame creates a shadow gap between the chimney and the ceiling. The ventilation hood can be installed with or without the spacer frame. g Recirculation vents Only for recirculation mode h Overhead lighting...
  • Page 14: Description Of Functions

    Description of functions The following functions are available on Recirculation mode your ventilation hood, depending on the The recirculation mode requires a model: recirculation kit and OdorFree Charcoal Filter (available as optional accessories, Extraction mode see “Technical Data” for more information) The air is drawn in and cleaned by the grease filters and directed outside.
  • Page 15: Operation

    Operation Turning on the blower Turning off the blower  Press the On/Off control  to turn Switch the blower on as soon as you start cooking. This is to ensure that the blower off. vapors are captured right from the start. The ...
  • Page 16: Turning Power Management On/Off

    Operation Turning power management on/off Safety shut-off You can deactivate power If power management has been management. deactivated, the ventilation hood will Keep in mind that this may increase switch itself off automatically after energy consumption. 12 hours if it has been left on (blower and overhead lighting).
  • Page 17: Energy-Saving Tips

    Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: - Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during extraction mode, the hood cannot operate efficiently, causing increased operating noise levels.
  • Page 18: Customer Service

    In the event of a fault which you cannot remedy yourself, please contact your Miele dealer or Miele Customer Service. You can book a Miele Service Call online at www.miele.com/service. Contact information for Miele Customer Service can be found at the end of this document.
  • Page 19: Cleaning And Care

    Unsuitable cleaning agents can treating them with a stainless steel care damage the surfaces and control product (available from Miele). elements. Do not use any cleaning agents Important information for the containing soda, acid, chloride, or controls solvent.
  • Page 20 Ensure the spray arm is not obstructed.  Use a commonly available household dishwashing detergent.  In a Miele dishwasher use the “Normal” program. Depending on the detergent used, cleaning the filters in a dishwasher may cause the inside filter surfaces to become discolored.
  • Page 21: Replacing The Grease Filter

    Charcoal filters are available to order via  Reinstall the grease filters. When the Miele Web Store, Miele Technical inserting the filters, make sure that Service (see end of this manual for the locking clip is facing down.
  • Page 22: Disposing Of Charcoal Filters

    Bulb type ......LED, GU10 Power ..........3W The bulb will then drop downwards. Light bulbs are available from Miele or  Grip the light bulb, turn it specialist dealers. counterclockwise and take it out.  Screw the new bulb into the socket and push it upwards.
  • Page 23: Installation

    *INSTALLATION* Installation Before installation  Before installation, it is important 14 screws, M4 x 8 mm to read the information contained in for securing the spacer frame and this chapter and in the “IMPORTANT securing the ventilation system to the SAFETY INSTRUCTIONS” chapter. installation frame.
  • Page 24: Appliance Dimensions

    *INSTALLATION* Installation Appliance dimensions a Mounting area for the exhaust ducting and power cable. In recirculation mode, only the power cord is required. b Possible height range for appliance in extraction mode c Possible height range for appliance in recirculation mode d Alternative installation with spacer frame e Air vent positioned at the top for recirculation...
  • Page 25: Distance Between Cooktop And Ventilation Hood (S)

    Please also observe the information contained in the “IMPORTANT SAFETY INSTRUCTIONS” section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26"...
  • Page 26: Installation Recommendations

    *INSTALLATION* Installation Installation recommendations Structural support - A distance of at least 26" (660 mm) is recommended above electric cooktops to provide more workspace and easier cooking under the hood. - When selecting an installation height, always take the user height into consideration.
  • Page 27 *INSTALLATION* Installation  For extraction mode: - Lay the vent duct and feed it down through the ceiling in the area shown. A section of flexible vent duct approx. 28" (700 mm) long is needed between the ceiling and the ventilation hood’s vent socket. ...
  • Page 28 *INSTALLATION* Installation  Use a knife to release the four spacers and the two covers from the spacer frame supplied.  Drill four holes  ³/₈“ (10 mm), approx. 4 ¹/₂” (115 mm) deep for the plugs supplied.  Use the spacer frame as a drilling ...
  • Page 29 *INSTALLATION* Installation The spacer frame can be installed between the chimney and the ceiling. This creates a shadow which gives the illusion of a gap between the ceiling and the chimney. This is useful if the ceiling  Mount the spacer frame onto the is not level or is uneven.
  • Page 30 *INSTALLATION* Installation  Hang the installation frame on the  Align the installation frame and four screws. The front of the frame is secure it with the screws. marked with a “V”. The spacers, which were removed  If using the spacer frame, place the from the spacer frame at the start, two covers into the fixing holes.
  • Page 31 *INSTALLATION* Installation  Holding the installation frame securely, remove the two fixing screws and extend the installation frame to its maximum length.  Replace the screws. The directional unit from recirculation kit DUI 32 (optional accessory) is installed for recirculation mode (RM): ...
  • Page 32 *INSTALLATION* Installation  Secure the hose to the directional unit socket using a hose clip.  Check that the hose is held securely.  Push the telescopic chimney over the installation frame: - with the recirculation grilles at the bottom for extraction mode (AE), - with the recirculation grilles at the top for recirculation mode (RM).
  • Page 33 *INSTALLATION* Installation  Fit the four telescopic chimney  Bend back the two retaining tabs. clamps. When the screws are  Push the chimney over the telescopic tightened, the clamps spread out and extension piece and bend the push the telescopic expansion piece retaining tabs outward again to upwards.
  • Page 34 *INSTALLATION* Installation A non-return flap is supplied with the hood or is already fitted in the exhaust socket of the motor unit (depending on model).  With vented mode (AE) insert the non-return flap in the exhaust socket if your ducting system is not equipped with one.
  • Page 35 *INSTALLATION* Installation  Connect the power cord. See “Electrical connection.”  Unscrew both screws from the installation frame again.  Slide the vent duct onto the vent The canopy can now be adjusted to the socket and secure it (using a hose desired height, observing the clip, for example).
  • Page 36 *INSTALLATION* Installation  Raise the canopy to the desired  Hold the chimney securely, bend height and secure it with the screws. back the retaining tabs and carefully lower it. The chimney will locate in the cut-out in the canopy.
  • Page 37 *INSTALLATION* Installation  With recirculation mode (RM) ventilation hoods, insert the OdorFree Charcoal Filter.  Remove the grease filters from the hood.  Insert the safety screw on the inside.  Carefully remove the protective foil from the grease filters. ...
  • Page 38: Air Venting

    “Appliance dimensions”). This applies If the exhaust is ducted through an in particular when using flat ducting. outside wall, a Miele wall vent or roof - The ducting should be as short and vent (available as an optional straight as possible.
  • Page 39: Condensate

    If the ducting is to run through cool the direction of airflow. rooms or ceiling space, for example, the significant variations in temperature Miele will not accept warranty claims between the different areas can cause for any functional defects or damage condensate to form. Insulate the caused by inadequate ducting.
  • Page 40: Electrical Connection

    If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department. WARNING: THIS APPLIANCE MUST BE GROUNDED The strain relief must be used to ensure...
  • Page 41: Technical Data

    Technical data Blower motor 350 W Overhead lighting 4 x 3 W Total connected load 362 W Supply voltage, frequency 120 V AC, 60 Hz Fuse 15 A Weight 74.8 lbs (34 kg) Optional accessories for recirculation mode DUI 32 conversion kit to change from vented mode to recirculation mode and DKF 12-900 OdorFree Charcoal Filter.
  • Page 43 Customer Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Headquarters and Miele Centre Princeton, NJ 08540 161 Four Valley Drive www.mieleusa.com Vaughan, ON L4K 4V8 www.miele.ca Customer Support Phone: 888-99-MIELE (64353) Customer Care Centre info@mieleusa.com...
  • Page 44 PUR 98 D en-US M.-Nr. 12 254 070 / 00...

Table of Contents