1
Description
1. Func�on LED Indicator
Link
Arm/Disarm
Fault
2. Power LED Indicator
6. Serial Port
3. Tag Present Area
7. Power Port
4. Tamper Switch
8. Power Switch
5. Reset Bu�on
9. Network Interface
Note: the SIM card func�ons vary depending on the model
2
Wiring and power On set up
3
Set Up
1.
Add the VX PRO to IDS VX PRO App.
2. Enroll the peripheral to the VX PRO.
Specification
Parameters
RF frequency
Wireless zones, Relay,
Smart Plug, Module & wall
switch
Wireless tag Reader &
Basic
keypad, Tag
Wireless Sounders, key
fobs, repeaters
PIR camera
IP camera integration
User
Installer, admin, user
Area
LEDs indication
So�ware
a
Memory Log stored
Programming tools
Wi-Fi(2.4G), LAN port,
LAN port
Communica�on
SIM slot
Protocal
Power supply
Hardware
Battery
Cer�fica�ons
EN Grade 2, CE, Rohs/Reach/WEEE
Consumption
Operation Environment
Others
Dimension(W x H x D)
170.0 mm (6.7") x 170.0 (6.7") mm x 38.6 mm (1.5")
Weight
Alarm
6. SIM Card 2 Slot
7. SIM Card 1 Slot
8. Serial Port
VX PRO
64 Series
96 Series
868Mhz/865Mhz
Up to 64
Up to 96
Up to 8, 32
Up to 8, 48
4, 32, 2
6, 48,4
2
4
0
4 x 7s clips
1, 1,30
1,1,46
16
32
Arm/Disarm, Alarm, Tamper, Fault, Cloud, Power
5000
5000
IDS VX Pro app
LAN port, Wi-Fi(2.4G), 3/4G
on board
GPRS on board
Single
Dual
SIA 09, Contact ID, ISUP
100 to 240 VAC
Built in on board Battery, Up to 12 hrs standby
100-240V to 50/60Hz, 0.1A-0.064A
Temperature: -10°C to 50°C, Humidity: 10 to 90%
557.5 g(19.7 oz)
Helpdesk : +27 (0) 87 159 7341
Product code : 0933393330939133
4
Installation
Tamper Screw (compulsory).
5
Reset
1. Restart the device, the power LED flashes 3 �mes.
2. Hold the reset bu�on on for 5 s.
EN 50131-1:2006+A2:2017
Environmental Class(EC) II
VX Pro
EN 50131-3:2009
EN 50131-6:2017
EN 50131-5-3:2017
EN 50131-10:2014
EN 50136-2:2013
Security Grade(SG)2
Cer fied by KIWA