Firman H08052 Operator's Manual page 19

Dual fuel portable generator

Advertisement

10. Allow portable generator to run at no load for a few minutes to stabilize before plugging in
any electrical devices.
NOTICE If engine starts but fails to run, or if portable generator shuts down during operation,
check oil level. See Low Oil Shutdown section for more information.
4. Starting the Generator on LPG
1. Before starting the generator, check for loose or missing parts and for any damage which may
have occurred during shipment. Ensure spark plug, muffler, fuel cap, and air cleaner are all in place.
2. Operate portable generator only outdoors and downwind at least 20 ft. (6 m) from occupied
spaces with exhaust pointed away to reduce the risk of carbon monoxide accumulating.
3. Connect the LPG hose with regulator to both LPG cylinder and portable generator LPG Hose
Connector (inlet).
4. Fully open the LPG cylinder knob.
5. Turn the main fuel selector switch to LPG position.
NOTICE When the main fuel selector switch is turned to the LPG position, the indicator light
will turn RED for up to 4 minutes (before going off). Starting the engine successfully anytime
during the 4 minutes will turn the indicator light GREEN.
See Indicator light-Battery Power Saving Mode section for more information.
English
LPG
18
OPERATION
Customer Service: 1-844-FIRMAN1