Download Print this page

Firman H08052 Operator's Manual page 10

Dual fuel portable generator

Advertisement

FEATURES AND CONTROLS
Control Panel
12

NOTICE
Total power drawn from all receptacles must not exceed the data decal rating.
1. Fuel Selector Switch – Use to select and turn on gasoline or LPG fuel source. Fuel (gasoline) valve is
closed when the switch is on "OFF" or "LPG" positions. Engine switch is on when the switch is on
"GAS" or "LPG" positions.
2. Indicator Light – When the main fuel selector switch is turned to the GAS or LPG position,
the indicator light will turn RED for up to 4 minutes (before going off). Starting the engine
successfully anytime during the 4 minutes will turn the indicator light GREEN. See Indicator
light-Battery Power Saving Mode section for more information.
3. Engine Start Switch – To start engine, press and hold the switch in the START (ll) position, the
engine will crank and attempt to start. When the engine starts, release the switch to the RUN (l) position.
4. 3-1 Data-Minder (Multi-Meter) – Push the SELECT button to show the Voltage, Hertz and running hours.
5. Circuit Breakers – The receptacles are protected by AC circuit protectors. If the generator is
overloaded or an external short circuit occurs, a circuit protector may trip. If tripping occurs,
disconnect all electrical loads and determine the cause before attempting to continue using the
generator. Reset any tripped circuit protectors.
If multiple receptacles are used at the same time, the total current must be kept with-in the
portable generator
6. 120V, 20A Duplex GFCI (Ground Fault Circuit Interrupter)- NEMA 5-20R
A maximum of 20 Amps current may be drawn from this duplex receptacle.
7. 120V, 30A Twist Lock – NEMA L5-30R(Not GFCI protected)
A maximum of 30 Amps current may be drawn from this receptacle.
8. 120/240V, 30A Twist Lock – NEMA L14-30R(Not GFCI protected)
A maximum of 30 Amps current for 240 Volts or two independent 120 Volt loads at 30 Amps current each.
9. Ground Terminal – Consult an electrician or authority having jurisdiction for local grounding
requirements.
10. 120/240V, 50A – (NEMA 14-50R) (Not GFCI protected)
A maximum of 33.33 Amps current for 240 Volts or two independent 120 Volt loads at 33.33 Amps current each.
11. Outlet Cover - Protects the receptacles from dust and debris.
12 . LPG Hose Connector (Inlet: 3/8" Flare Male) – Used to connect LPG hose to generator.
13. CO Alert™ Carbon Monoxide (CO) Shutdown Indicator Light — Indicates the engine shutdown due
to carbon monoxide accumulation around the generator or a CO Alert system fault occurred.
English
1
5
data decal
rating.
2
3
4
13
10
11
09
5
9
8
7
Customer Service: 1-844-FIRMAN1
6

Hide quick links:

Advertisement

loading