REPAIR AND MAINTAINANCE / SERVICE OCH UNDERHÅLL
GENERAL / ALLMÄNT / GÉNÉRALITÉS
AIR SENSORS
The air sensors are on the inside part of the diaphragm covers. To access
them, follow the procedure for "replacing diaphragms".
Once the covers are removed follow this procedure:
1.
Remove the two screws holding the air sensor.
2.
Remove all components of the sensor, clean the area.
3.
Install the new components in the order shown.
4.
Fit the cover and tighten the screws with a torque according to the
table on page 9. Remount the remaining components in reverse order.
PUMP

DIAPHRAGM COVER

1/2" (38 l/min) 70,91 lbf in (8Nm)
1/2" (50 l/min) 48.7-53.1 lbf in (5,5-6Nm)
1" (100 l/min)
137.7 lbf in (15Nm)
Alentec & Orion AB Grustagsvägen 4, SE-13840, Älta, SWEDEN · info@alentec.se · www.alentec.com
EN
RIKTNINGSSENSORER
Riktningssensorerna är placerade på insidan av membrankåporna. För att
komma åt dem följ anvisningarna i kapitel "Byte av membran".
När kåporna är loss följ instruktionerna nedan:
1.
Ta loss de två skruvar som håller sensorerna på plats.
2.
Ta loss alla delar av sensorn och rengör området de satt i.
3.
Montera de nya delarna i den ordning som visas nedan.
4.
Sätt tillbaka kåporna, använd momentnyckel inställd enligt tabell på
sida 9. Montera återstående delar av pumpen.

DIRECTIONAL VALVE

44.25 lbf in (5Nm)
44.25 lbf in (5Nm)
44.25 lbf in (5Nm)
VALVE CAP
30.9 lbf in(2Nm) composite
35.5 lbf in (4Nm) aluminium
30.9 lbf in(2Nm) composite
35.5 lbf in (4Nm) aluminium
30.9 lbf in(2Nm) composite