Page 1
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The...
Table of contents 1. Introduction ....................2 2. Appearance ....................3 3. Main Features .................... 4 4. Set up Instruction ..................5 5. Data Report ....................6 6. Application ....................9 7. Installation ....................10 8. Maintenance and maintenance ..............11...
R831A is a high-reliability switch control device which is a Class C device of netvox based on the LoRaWAN open protocol. The device is compatible with LoRaWAN protocol. R831A is a device used to control the switch and is mainly used for the switch control of the strong electric motor control box.
2. Appearance Status Indicator Network Indicator Port 1 Port 2 Port 3 DIP Switch Port 4 Port 5 R831A Port 6 DIP SW Port 7 DIP Switch (Change R831 series mode) 3.3V Local switch-Forward Function Key Local switch-Reverse Local switch-Stop...
⚫ Applicable to third-party platforms: Actility/ThingPark, TTN, MyDevices/Cayenne ⚫ Improved power management for longer battery life Battery Life: ⁻Please refer to web: http://www.netvox.com.tw/electric/electric_calc.html ⁻At this website, users can find battery life time for variety models at different configurations. 1. Actual range may vary depending on environment.
4. Set up Instruction On/Off Power On External 12V power supply Turn On After plug the power, the status indicator will stay on, it means the boot is successful. Restore To Factory Setting Press and hold the function key for 5 seconds till the status indicator flashes 20 times. Power Off Remove power Note:...
The interval between two reports must be the MinTime. If there are special customized shipments, the setting will be changed according to customer’s requirements. Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://www.netvox.com.cn:8888/page/index to resolve uplink data.
Page 9
Motor Switch Configuration (3) Motor Reverse Downlink:90B2000000000000000000 (4) Motor Advance Downlink:91B2000000000000000000 (5) Switch Motor State (Change from forward to reverse or from reverse to forward) Downlink:92B2000000000000000000 (6) Motor Stop Downlink:95B2000000000000000000 Switch Type Configuration (7) Setting switch type is tact type switch Downlink:03B2010000000000000000 Response:83B2000000000000000000 (Configuration success) (8) Confirm switch type...
Example for MinTime/MaxTime logic: Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour MaxTime MaxTime (MinTime) (MinTime) Collects data Collects data Collects data REPORTS ON REPORTS ON REPORTS OFF Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless ON/OFF value. Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour MaxTime MinTime...
(If the DIP switch is not correctly toggled, the network lights and status lights will flash alternately,users need to dial power down and power on again.) (1) R831A - strong electric motor mode: Toggle the DIP switch 1 This mode has two relays involved in operation which are combined for on / off / stop.
8. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the equipment dry. Rain, moisture and various liquids or water may contain minerals that can corrode electronic circuits. In case the device is wet, please dry it completely.
Need help?
Do you have a question about the R831A and is the answer not in the manual?
Questions and answers