1. Introduction Netvox Z503, a ZigBee local commander, can be bound with the lighting/ curtain/ dimmer devices for users to control these devices wirelessly. It allows people to perform the scene controls, and each button is programmable. Z503 also equipped with an emergency button. When users ask for urgent assistance, simply push the button, and it will send the alarm message to the command center.
4. Installation This device is NOT truly waterproof/ resistant and is for indoor use. 5. Setting up Z503 5-1. Join the ZigBee Network (1) While Z503 is under the coverage from a coordinator or a router whose permit-join feature is enabled, Z503 will be permitted to join the network.
Page 7
Left: Front view Right: Back view Open the battery cover Insert the Battery Holder battery The battery is Install the installed battery cover...
5-2. Binding Only in HA network, Z503 can be bound with the device which supports HA On/Off Output/ HA Level Controllable Output/ HA Mains Power Outlet/ HA On/Off Light/ HA Dimmable Light/ HA Color Dimmable Light/ HA Shade/ HA Heating Unit/ HA Cooling Unit/ HA Pump (such as Z800/ Z801RX/ ZC01/ Curtain controller/ Dimmer Light).
5-3. Group Build up In Zll network, Z503 is able to establish group, and control devices in the group. If users do not establish a group, there are three corresponding methods to establish groups: ① Turn on the identify function of devices which will be in the group. Press and hold for more than three seconds);...
5-5. Emergency After binding with IAS devices, press to send emergency message to the network. 5-6. Arm/Disarm Security After finding out CIE device (please refer to 5-1. Join the ZigBee Network), users area able to arm/disarm the security through Z503. ...
5-8. Configure Scene and Get Scene Configuration Support “Configure Scene” and “Get Scene Configuration” functions and control up to four scenes each key 5-9. Recall Scene less than 3 seconds t Press Scenario o recall scene. When configurating to switch saved more than once scene through “Configure Scene”, press scenes.
5-12. Wake up Z503 When users would like to setup or acquire data from the device which is in sleeping mode, we have to wake to wake it up. After up the device. To wake up Z503, press and hold first.
7. Netvox APP Control Interface 1. After the device is added to the Netvox system, search for the IEEE address in the device management interface of the APP as shown in following figure: note: 00137A000000DC64 - 0F (IEEE - EP )
Page 16
2. Select Remote Control as shown in following figure:...
Page 17
3. Click Pairing configuration and the following screen appears: You will see the EP supported by the device Note:00137A000000DC64 - 01 ( IEEE - EP ) Pairing configuration: EP 01 ~ 03 Corresponding to Lamp 1 ~ Lamp 3 buttons EP 04-05 Corresponding to dimmer 1 (up / down) to dimmer 2 (up / down) buttons EP 06 ~ 08 corresponds to the Outlet 1 ~ Outlet 3 buttons EP 09 to 0B corresponds to the Curtain 1 (Up / Down) to Curtain 2 (Up / Down) buttons...
Page 18
Click scene configuration, the following interface will appear. You will see EP support scene function Note: 00137A000000DC64 - 0E( IEEE - EP ) Scene configuration: EP 0E ~ 11 corresponds to "1", "2", "3" three scene button. Each EP can be bound to four scenario actions.
8. Important Maintenance Instructions Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture can contain minerals that corrode electronic circuits. In cases of accidental liquid spills to a device, please leave the device dry properly before storing or using.