b) Fuses
F1 Fuse .......................................... Φ 6 x 32 mm, FF 10 A, H 600 V, Breaking capacity:10 KA
F2 Fuse .......................................... Φ 5 x 20 mm, FF 600 mA, H 600 V, Breaking capacity: 500
c) Measurement tolerances
Accuracy: ± (% of reading + count)
The accuracy is valid for one year at:
•
Ambient temperature: +3 °C (± 5 °C), ≤75 %, RH non-condensing
•
Operating temperature*: 18 to 28 °C (±1 °C)
*A temperature coefficient applies outside of this temperature range: +0.1 x (specified accuracy)
/ °C.
The measurement can be impaired when the device is operated within a high-frequency
electromagnetic field.
d) Capacitance measurement
Range
6.000 nF
60.00 nF
600.0 nF
6.000 uF
60.00 uF
600.0 uF
6.000 mF
60.00 mF
Overload protection: 600 V
66
Input terminal protection (A)
A min.
Input terminal protection (μA, mA)
Resolution
0.001 nF
0.01 nF
0.1 nF
0.001 uF
0.01 uF
0.1 uF
0.001 mF
0.01 mF
Accuracy
± (5.0 % + 10)
± (3.5 % + 9)
± (3.5 % + 5)
± (5.0 % + 5)
± (8.0 % + 5)