b) Fuses

F1 Fuse .......................................... Φ 6×32 mm, FF 10 A, H 600 V, Breaking capacity:10 KA
F2 Fuse .......................................... Φ5×20 mm, FF 400 mA H 600 V, Breaking capacity: 500 A

c) Measurement tolerances

Accuracy: ± (% of reading + count)
The accuracy is valid for one year at:
Ambient temperature: +3 °C (± 5 °C), ≤75 %, RH non-condensing
Operating temperature*: 18 to 28 °C (±1 °C)
*A temperature coefficient applies outside of this temperature range: +0.1 x (specified accuracy)
/ °C.
The measurement can be impaired when the device is operated within a high-frequency
electromagnetic field.

d) Capacitance measurement

Range
40.00 nF
400.0 nF
4.000 - 100.0 uF
Overload protection: 600 V
Input terminal protection (A)
min.
Input terminal protection (μA, mA)
Resolution
0.01 nF
0.1 nF
0.001 - 0.1 uF
Accuracy
± (4 % + 10)
± (4 % + 3)