B) Fuses; C) Measurement Tolerances; D) Dc Voltage Measurement - VOLTCRAFT VC151 Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

b) Fuses

F1 Fuse .......................................... ø5 x 20 mm, FF 400 mA H 600 V,
F2 Fuse .......................................... ø6 x 32 mm, FF 10 A, H 600 V,

c) Measurement tolerances

Accuracy: ± (% of reading + count)
The accuracy is valid for one year at:
Ambient temperature: +3 °C (± 5 °C), ≤75 %, RH non-condensing
Operating temperature*: 18 to 28 °C (±1 °C)
*A temperature coefficient applies outside of this temperature range: +0.1 x (specified accuracy)
/ °C.
The measurement can be impaired when the device is operated within a high-frequency
electromagnetic field.

d) DC voltage measurement

Range
4.000 V
40.00 V
400.0 V
600 V
Input impedance: approx 10 MΩ
Input voltage: max. 600 V
56
Breaking capacity: 500 A min.
Input terminal protection (μA, mA)
Breaking capacity: 10 KA,
Input terminal protection (A)
Resolution
0.001 V
0.01 V
0.1 V
1 V
Accuracy
± (0.7 % +6)