Wiring Instructions
Notes:
1.
Larger wires and tight connections will provide longer service life for components. For high current wires it is highly recommended
that terminal blocks or soldered connections be used with shrink tubing to protect the connections. Do not use insulation displacement
connectors (e.g., 3M Scotchlock type connectors).
2.
Route wiring using grommets and sealant when passing through compartment walls. Minimize the number of splices to reduce voltage
drop. All wiring should conform to the minimum wire size and other recommendations of the manufacturer and be protected from moving
parts and hot surfaces. Looms, grommets, cable ties, and similar installation hardware should be used to anchor and protect all wiring.
3.
Fuses or circuit breakers should be located as close to the power takeoff points as possible and properly sized to protect the wiring and
devices.
4.
Particular attention should be paid to the location and method of making electrical connections and splices to protect these points from
corrosion and loss of conductivity.
5.
Ground termination should only be made to substantial chassis components, preferably directly to the vehicle battery.
6.
Circuit breakers are very sensitive to high temperatures and will "false trip" when mounted in hot environments or operated close to their
capacity.
IMPORTANT! Disable power before wiring the beacon.
The wiring configuration is shown in Figure 3. All wiring should be
a minimum of 18AWG. A switch may be used to control the on/
off function. The black (negative) wire is connected to the battery
ground.
Flash Patterns
Flash Pattern Selection:
Flash patterns can be selected by touching the Blue wire to the
Black wire according to the Push Times table below.
PUSH TIMES
0 ~ 1 sec.
1 ~ 3 sec.
3 ~ 5 sec.
5 ~ sec.
Pattern No.
Pattern Name
1
Single Flash Phase 1
2
Single Flash Phase 2
3
Double Flash Phase 1
4
Double Flash Phase 2
5
Triple Flash Phase 1
6
Triple Flash Phase 2
7
Quad Flash Phase 1
8
Quad Flash Phase 2
9
Quint Flash Phase 1
10
Quint Flash Phase 2
11
R65 Single Flash Phase 1
12
R65 Single Flash Phase 2
13
R65 Double Flash Phase 1
14
R65 Double Flash Phase 2
15
R65 Quad Flash Phase 1
16
R65 Quad Flash Phase 2
17
18
Steady Burn
FUNCTION
Next Pattern
Previous Pattern
Factory Default Pattern
Last Pattern
SYNC
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Random
No
No
3A Fuse
3A FUSE
(USER SUPPLIED)
(USER SUPPLIED)
+
-
Synchronization:
Connect all yellow wires together to synchronize the units in phase
A or B. For alternate flash mode set some beacons in phase A and
some in B.
FPM
75
75
75
75
75
75
75
75
150
150
120
120
120
120
120
120
N/A
N/A
RED
RED
YELLOW
YELLOW
SWITCH
SWITCH
BLUE
BLUE
(USER SUPPLIED)
(USER SUPPLIED)
BLACK
BLACK
GROUND
GROUND
GROUND
GROUND
Figure 3
SYNCHRONIZATION
SYNCHRONIZATION
(ISOLATE WHEN NOT IN USE)
(ISOLATE WHEN NOT IN USE)
PATTERN SELECT TO GROUND/
PATTERN SELECT TO GROUND/
DIM TO POSITIVE
DIM TO POSITIVE
(ISOLATE WHEN NOT IN USE)
(ISOLATE WHEN NOT IN USE)
Page 3 of 5