 Model: AOHG12KPCA
Fan speed is defined by outdoor temperature and rotation number of the compressor.
• Outside air temperature zone selection
Fan step
S-HIGH2
S-HIGH1
HIGH
10
9
8
7
6
5
4
3
2
1
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
rotation number of compressor.
Fan speed after defrost control: 1,020 rpm
3-2. Outdoor fan control
Outside air
temperature rises
21°C
12°C
2°C
Cooling
Heating
Y zone
1,020
950
1,020
950
1,020
790
950
790
900
790
900
790
900
790
900
730
800
630
680
530
580
470
540
470
Outside air
temperature drops
Y zone
Z zone
F zone
G zone
Dry
Cooling or dry at low outdoor temp.
Y zone
Z zone
950
950
900
900
900
900
900
560
900
420
800
350
680
350
580
350
540
350
- (04-13) -
19°C
10°C
0°C
Unit: rpm
F zone
G zone
950
350
350
350
320
290
270
270
250
950
300
300
300
230
230
230
230
230