Electronics for speed-controlled stationary rotary screw compressor (32 pages)
Summary of Contents for Gardner Denver THOMAS SK927
Page 1
MODEL SK927 FILTER REPLACEMENT COMPRESSOR SERVICE KIT 1. Remove filter cap. 2. Remove old filter and discard. For service to 917/927 Series Compressors 3. Wipe inside of filter body and cap with a clean soft cloth. CAUTION: Improper assembly or use of damaged parts may lead to premature failure.
Page 2
DIAPHRAGM REPLACEMENT INTAKE & EXHAUST VALVE REPLACEMENT 1. Remove head. 1. Remove 4 head screws and head. Discard screws. Turn head over. Remove 4 screws 2. Remove four screws from hold down plate. Discard screws. from valve plate. Discard screws. Remove valve plate from head.