[n: Timeout setting]
Timeout of 'Image Capture mode' can be set in units of seconds. The effective values are 0 (000) ~
999. For 'Commands in Conjunction mode (m = 0)', the timeout value is ignored. The timeout period is
measured from command reception to capturing. When n=0, there is no timeout and the scan engine
will wait indefinitely for a trigger input. When n > 0, this value specifies the timeout period in seconds.
n
0
None
1 – 999
Specified periods [second]
When there is no trigger input during timeout period 't', image capture mode is turned off after the 't'
expires. Normal decoding will then be performed by subsequent trigger inputs.
In Trigger Capture (2) mode, the trigger needs to be released during the period of 't' to take a picture.
If it is not released, the aiming stops after 't' expires and Image Capture mode is turned off. If the
trigger is released, no operation is performed.
Image Capture
Mode
Trigger
Aiming
Image Capture
In Trigger Capture (3) mode, the trigger needs to be pressed twice during the period of 't' to take a
picture. Aiming will turn on after the first trigger and it will be turned off after 't' expires. Normal
decoding will be performed with the second trigger in that case.
Image Capture
Mode
Trigger
Aiming
Image Capture
Timeout period
t
t
8
MDI-4x00 / N210 Image Capture
Image Capture Manual
Remark
Wait indefinitely for a trigger