Using The I-Control Ampere Function (Optional) - LG APNQ55GT3M2 Owner's Manual

Table of Contents

Advertisement

Using the I-Control Ampere
Function (Optional)
1
Turn the appliance on.
2
Press
^
button.
- Press
button repeatedly to select each
^
step.
NOTE
• 1 step : The power input is setting
around α A to operate the appliance.
• 2 step : The power input is setting
around β A to operate the appliance.
will be blinking on the indoor unit,
when the air conditioner needs more
Ampere for operating than setting
ampere's operation range.
- If you change the step by pressing
Ampere Ctrl button,
disappeared.
- Display icon may not appear depending
on the model accordingly.
• This function is available with Cooling
Mode.
• Capacity may decrease when I-Control
Ampere mode is selected.
• Desired temperature is displayed about 5
seconds if you press Fan Speed,
H
button.
• Some functions may not be supported,
depending on the model.
• Name of the function may differ
depending on the model accordingly.
How to use I-CONTROL AMPERE
APNW36GT3S1
APNW50GT3E0
APNW36GT2E4
• Above recommended figures are based on
blinking will be
G
or
OPERATING INSTRUCTIONS
I-Control Ampere
Model
Display
Ampere Range
Normal
National Power
A1, 12A(α) 11.0 ~ 13.9 Amperes
A2, 8A(β)
7.0 ~ 9.9 Amperes up to 46 °C Click 2 time
Normal
National Power
A1, 14A(α) 12.0 ~ 17.9 Amperes
A2, 10A(β)
8.0 ~ 13.9 Amperes up to 46 °C Click 2 time
Normal
National Power
A1
11.0 ~ 13.9 Amperes
A2
8.0 ~ 10.9 Amperes up to 46 °C Click 2 time
laboratory testing under following
conditions:
- Standard voltage (220 V ±15 %)
- Properly insulated room
- Suitable A/C tonnage for room size
- Correctly installed unit with R410A gas and
vacuum work
25
Temperature
Ampere
Range
Control button
-
up to 54 °C
Click 1 time
-
up to 54 °C
Click 1 time
-
up to 54 °C
Click 1 time

Advertisement