End Caps / Connections
End caps are to be field supplied and to be of the following materials:
•
Cold water cap - Brass or Copper
•
Hot water cap - Brass or Copper
•
Gas cap - black iron
Once flow direction and gas supply side is determined the other (opposite) side of the manifold must be capped.
See the example below.
Leak check the capped ends of the manifolds.
CAP
COLD IN
CAP
36
HOT OUT
CAP
GAS IN
Rinnai Rack Installation