Summary of Contents for Rothenberger RO 3200

  • Page 1 RO 3200 EN Instructions for use rothenberger.com MAN00146 ENGLISH...
  • Page 2: Table Of Contents

    Contents Page RO 3200 Overview ..........4 General Operation ..........4 On/Off ................4 Zero .................4 Change units ..............5 Before usi ng the meter for the first time ... 5 Before using the meter every time ..... 5 Unit options ............6 Measuring ............
  • Page 3: 3200 Overview

    RO 3200 Overview ● +/-200 mbar range ● 8 user selectable scales ● Temperature compensated ● One button zeroing ● Long battery life ● Robust case with integrally moulded protective boot ● Integral magnets for hands-free operation General Operation The meter is controlled using 2 buttons.
  • Page 4: Change Units

    Change units Quickly press and release The display will show the units currently set eg HPA. Now press to scroll through the selection of units available. When the units of choice are displayed, press to select. Before using the meter for the first time Remove the cover and fit a new battery in the battery compartment.
  • Page 5: Unit Options

    Unit options PS UNITS User selectable units are mBAR, inH20, hPa, mmHg, PSI, kPa, Pa, mmH2O These are displayed as follows: mmHg inH2O mBar mmH20 ENGLISH...
  • Page 6: Measuring

    Measuring Make sure you do not exceed the meter’s operating specifications. Do not exceed the meter’s internal temperature operating range Do not put the meter on a hot surface When taking critical draft measurements always re-zero the meter in the position you are taking the readings and hold the meter still during the test.
  • Page 7: Specification

    Specification Scale Range Highest resolution Mbar ±200 0.01 ±9999 ±200 0.01 ±20 0.001 ±3.0 0.001 mm Hg ±150 0.001 mm Wg ±2100 In Wg ±80 0.01 NOTE: The nominal range is plus and minus 200 mbar. The meter does not fully auto-range and so when Pa units are selected the full operating range cannot be displayed and the user must select an alternative range for measurements above 9999 Pa.
  • Page 8: Electromagnetic Compatibility

    Ambient Operating Range: 0oC to 45oC 10% to 90% RH non-condensing Power Supply: 9 Volt PP3 alkaline battery Electromagnetic compatibility European Council Directive 89/336/EEC requires electronic equipment not to generate electromagnetic disturbances exceeding defined levels and have adequate immunity levels for normal operation. Specific standards applicable to this meter are stated below.
  • Page 9: Cold Weather Precautions

    Cold weather precautions It is important you keep your product in a warm place overnight Electronic devices that become really cold, by being left in a vehicle over- night, suffer when taken into a warm room the next morning. Condensation may form which can affect the product’s performance & cause permanent damage Electrochemical sensors can be affected by condensation or water.
  • Page 10 Register your RO 3200 Register your RO 3200 to create your KAM dashboard: Simple online booking on www.kane.co.uk ★ Automatic reminder when due for recertification ★ FREE POSTAGE returning your Rothenberger analyser ★ SAME DAY annual FGA recertification OR YOUR MONEY BACK* ★...
  • Page 11 ROTHENBERGER Werkzeuge GmbH Industriestraße 7 D-65779 Kelkheim / Germany Telefon +49 6195 / 800 - 0 Telefax +49 6195 / 800 - 3500 info@rothenberger.com ROTHENBERGER (UK) LIMITED 2 Kingsthorne Park Henson Way Kettering Northants NN16 8PX Tel: +44 (0) 1536 310300 Fax: +44 (0) 1536 310600 E: info@rothenberger.co.uk...